8
DESTINATIoN SETTINGS
8-8
Destination Settings screen
Destination Settings > Destination Settings
■
Destination Settings (All)
4
IP Transceiver Controller/
Connection Port �����
Select the communication devices.
•
IP Transceiver Controller*¹
•
Digital Transceiver1 (D-TRX1) ~ Digital Transceiver4 (D-TRX4)
•
EXT I/O1 (EXT1) ~ EXT I/O4 (EXT4)*²
•
Emergency Notification
•
Microphone (MIC)
•
RoIP Gateway1 ~ RoIP Gateway8
*¹ Displayed when an IP Transceiver Controller is connected.
*² When [Connected Unit] is set to “EXT I/o Unit” and [EXT I/o Port
Mode] is set to “Separate” in [EXT I/o Port Mode] setting (Connection
Port Settings > EXT I/o (EXT) > EXT I/o Port Mode), “EXT Input”
and “EXT output” are displayed.
L
When clicking “All,” you can select or cancel all at once.
L
When a speaker microphone is connected to the [MIC] port, the audio input/
output of the [EXT1] port is disconnected.
The Audio input/output of the [MIC] port and the [EXT1] port cannot be used
at the same time.
L
The other bases in [Additional Controller] (
3
) and [IP Transceiver Controller/
Connection Port] (
4
) can be connected to a total of up to 22 locations.
(“IP Transceiver Controller” is not included this number of connections.)
If you connect the other bases to more than 22 locations, you cannot
communicate properly.
5
<Apply> ��������
Click to apply the entries.
L
The registered contents are displayed in [List of Destination Setting Entries (All
Call)].
6
<Reset> ��������
Click to reset the settings.
L
You cannot reset after clicking <Apply>
This is an example of setting “All” as the Call Type.
1
2
3
6
4
5