9
ExPERT SETTINGS
9-4
Abnormal Condition Monitoring screen
■
PING Test
Set the monitor function for a communication error.
Expert Settings > Abnormal Condition Monitoring
1
4
3
2
1
Monitoring �������
Select whether or not to send PING commands to the host specified by
the IP address. When the error is detected, the error is displayed on the
“SYSLOG” screen. (Information > SYSLOG >SYSLOG)
(Default: Disable)
2
Control Output
�����
Select whether or not to short the B1/B2 terminal (+/–) to output an
error detect signal.
(Default: Disable)
L
Confirm the Relay Circuit is selected.
( Connection Port Settings > ExT I/O (ExT) > ExT Output Settings >
Switching Control)
3
IP Address
�������
Enter the destination IP address to send the PING commands to.
4
Monitoring Period
����
Set the monitor period.
(Default: 10)
• Range: 1 ~ 4320 (minutes)
L
2
~
4
are displayed only when Monitoring (
1