163
14
MAINTENANCE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
N
Fuse replacement
If the fuse blows or the transceiver stops functioning, find the
source of the problem if possible, and replace the blown fuse
with a new, properly rated one (FGB 20 A) as shown at right.
20 A
fuse
PROBLEM
POSSIBLE CAUSE
SOLUTION
REF.
Scan does not operate.
• The squelch is open.
• Only one memory channel is programmed or
other channels are set as skip channels.
• Set the squelch to the threshold point.
• Program other memory channels or cancel the
memory skip function in the desired channels.
p. VIII
pgs. 90,
108
Transmission is automati-
cally cut off.
• Time-out timer is activated.
• Set the timer to OFF.
p. 157
Transmission continues
even when the PTT is re-
leased.
• One-touch PTT function is activated.
• Turn the function OFF.
p. 21
D u r i n g t o n e s q u e l c h o p -
eration, the received audio
breaks off at the other station.
• Transmitter’s microphone gain is too high.
• Select low microphone sensitivity in FUNC set
mode.
• Turn the ALC function ON in FUNC set mode.
p. 127
p. 127
The function display shows
erroneous information.
• The CPU is malfunctioning.
• Reset the CPU.
p. 154