806f0107-0304ffff
An Over-Temperature Condition has been detected on [ProcessorElementName].
Explanation:
The microprocessor 4 temperature has risen above the critical level, causing a hard shutdown of the
node.
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0036
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Check the IMM event log for any fan or cooling related issues.
2.
Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3.
Make sure that the room temperature is within operating specifications.
4.
Make sure that the microprocessor 4 heat sink is securely installed.
5.
(Trained service technician only) Make sure that the microprocessor 4 heat sink is installed correctly and the
thermal material is correctly applied.
6.
(Trained service technician only) Replace microprocessor 4.
806f0108-0a01ffff
[PowerSupplyElementName] has Failed.
Explanation:
IMM has detected a Fault on Power Supply 1.
Severity:
Error
Alert Category:
Critical - Power
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0086
SNMP Trap ID:
4
Automatically notify Support:
Yes
User response:
Check the log for additional Power Supply Failure. Replace the Power Supply 1, if needed
806f0108-0a02ffff
[PowerSupplyElementName] has Failed.
Explanation:
IMM has detected a Fault on Power Supply 2.
Severity:
Error
Alert Category:
Critical - Power
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0086
SNMP Trap ID:
4
Automatically notify Support:
Yes
User response:
Check the log for additional Power Supply Failure. Replace the Power Supply 2, if needed
806f0107-0304ffff • 806f0108-0a02ffff
460
System x3750 M4 Types 8722 and 8733: Installation and Service Guide
Summary of Contents for System x3750 M4 Type 8733
Page 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Page 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 693: ......
Page 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...