Memory problems
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 5, “Parts listing, System x3750 M4 Types 8722 and 8733,” on page 195 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
Symptom
Action
The amount of system memory
that is displayed is less than the
amount of installed physical
memory.
Note:
If you change memory, you must update the memory configuration in the
Setup utility (see “Using the Setup utility” on page 127 for more information). For
more information about installing DIMMs, see “Installing a memory module” on
page 41, “Non-mirroring (independent mode)” on page 44, “Memory mirroring”
on page 44, and “Memory sparing” on page 45.
1.
If the server was recently installed, moved, or serviced, make sure that all
DIMMs are seated correctly.
2.
If a new DIMM has been installed recently, verify that you have not received
any configuration events in the event log. Otherwise, check the IMM event log.
If any DIMM configuration events are listed, resolve the event problems first.
3.
Make sure that:
v
No error LEDs are lit on the operator information panel or on the
microprocessor and memory expansion tray.
v
Memory mirroring does not account for the discrepancy (see “Memory
mirroring” on page 44).
v
The memory modules are seated correctly (see “Removing a memory
module” on page 223 and “Replacing a memory module” on page 224).
v
You have installed the correct type of memory (see “Installing a memory
module” on page 41).
v
If you changed the memory, you updated the memory configuration in the
Setup utility.
v
All banks of memory are enabled. The server might have automatically
disabled a memory bank when it detected a problem, or a memory bank
might have been manually disabled.
4.
Check the POST event log:
v
If a DIMM was disabled by a systems-management interrupt (SMI), replace
the DIMM.
v
If a DIMM was disabled by the user or by POST, run the Setup utility and
enable the DIMM.
5.
Run memory diagnostics (see “IBM Dynamic System Analysis” on page 169). If
an error is detected, follow the steps to correct the error.
6.
For the system board and microprocessor and memory expansion tray, add
DIMMs one at a time ( see “Replacing a memory module” on page 224).
7.
Reseat the DIMM.
8.
Restart the server.
Multiple rows of DIMMs in a
branch are identified as failing.
1.
Check the system-event log for any events associated with a failing DIMM.
2.
Resolve the DIMM errors listed in the system-event log, starting with the first
error that has occurred.
3.
Resolve any DIMM configuration mismatches that are listed in the IMM event
log.
180
System x3750 M4 Types 8722 and 8733: Installation and Service Guide
Summary of Contents for System x3750 M4 Type 8733
Page 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Page 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 693: ......
Page 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...