80070201-0303ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation:
IMM has detected a CPU 3 temperature Sensor has transitioned to critical.
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1.
Check the IMM event log for any fan or cooling related issues.
2.
Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3.
Make sure that the room temperature is within operating specifications.
80070201-0304ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation:
IMM has detected a CPU 4 temperature Sensor has transitioned to critical.
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1.
Check the IMM event log for any fan or cooling related issues.
2.
Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3.
Make sure that the room temperature is within operating specifications.
80070202-0701ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation:
The Planar Fault sensor has detected a problem with the system board.
Severity:
Error
Alert Category:
Critical - Voltage
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
1
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Remove any recently installed components.
2.
Try to power on the node.
v
If the node successfully powers on, complete the following steps:
a.
Check the ServerProven website to make sure that recently installed components are compatible with the
compute node.
b.
Inspect the previously installed components for physical damage.
80070201-0303ffff • 80070202-0701ffff
418
System x3750 M4 Types 8722 and 8733: Installation and Service Guide
Summary of Contents for System x3750 M4 Type 8733
Page 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Page 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 693: ......
Page 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...