Attention:
Some cluster solutions require specific code levels or coordinated code
updates. If the device is part of a cluster solution, verify that the latest level of
code is supported for the cluster solution before you update the code.
Note:
v
For additional information and notes about installing adapters, see “Installing an
adapter” on page 66.
v
Follow the general rule for connecting the SAS signal cables to the adapter and
drive backplane: port 0 on the adapter to port 0 on the drive backplane and port
1 on the adapter to port 1 on the drive backplane (depending on the type of
drive backplane you install in the server).
To install the adapter if your server model did not come with this adapter,
complete the following steps.
1.
Read the safety information that begins on page “Safety” on page vii and
“Installation guidelines” on page 33.
2.
Turn off the server (see “Turning off the server” on page 21) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables from the server.
3.
Remove the top cover (see “Removing the server top cover” on page 36).
4.
Remove the fan cage assembly (see “Removing the fan cage assembly” on
page 40).
5.
Remove the microprocessor and memory expansion tray (see “Removing the
microprocessor and memory expansion tray assembly” on page 278) or DIMM
air baffle (see “Removing the DIMM air baffle” on page 210), whichever one is
installed.
6.
Grasp the riser-card assembly by the blue touch points and pull it up until the
riser-card assembly disengages from the connector on the system board; then,
set it aside.
7.
Touch the static-protective package that contains the adapter to any unpainted
surface on the outside of the server; then, grasp the adapter by the top edge
or upper corners of the adapter and remove it from the package.
8.
Make sure that a full-height bracket is installed on the card.
9.
Open the PCIe retention latch.
10.
Align the adapter so that the keys align correctly with the connector on the
riser-card assembly.
11.
Insert the adapter into the connector on the riser-card until it is firmly seated.
Attention:
Incomplete insertion might cause damage to the server or the
adapter.
12.
Close the PCIe retention latch.
13.
Connect the SAS cables to the adapter.
14.
Reinstall the riser-card assembly onto the system board.
15.
Route the signal cables through the SAS cable guide and connect the signal
cables to the drive backplane.
Note:
Follow the general rule for connecting the SAS signal cables to the
adapter and drive backplane: port 0 on the adapter to port 0 on the drive
backplane and port 1 on the adapter to port 1 on the drive backplane
(depending on the type of drive backplanes you installed in the server).
74
System x3750 M4 Types 8722 and 8733: Installation and Service Guide
Summary of Contents for System x3750 M4 Type 8733
Page 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Page 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 693: ......
Page 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...