806f000f-220201xx
The System [ComputerSystemElementName] has detected no memory in the system.
Explanation:
IMM has detected no memory in the system.
Severity:
Error
Alert Category:
Critical - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0794
SNMP Trap ID:
41
Automatically notify Support:
No
User response:
Sys Boot Status :This is a UEFI detected event. The UEFI diagnostic code for this event can be found
in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the
Info Center for the appropriate user response.
806f000f-220202xx
Subsystem [MemoryElementName] has insufficient memory for operation.
Explanation:
IMM has detected that the usable Memory is insufficient for operation.
Severity:
Error
Alert Category:
Critical - Memory
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0132
SNMP Trap ID:
41
Automatically notify Support:
No
User response:
Sys Boot Status :This is a UEFI detected event. The UEFI diagnostic code for this event can be found
in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the
Info Center for the appropriate user response.
806f000f-220203xx
The System [ComputerSystemElementName] encountered firmware error - unrecoverable boot
device failure.
Explanation:
IMM has detected that System Firmware Error Unrecoverable boot device failure has occurred.
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0770
SNMP Trap ID:
5
Automatically notify Support:
No
User response:
Sys Boot Status :This is a UEFI detected event. The UEFI diagnostic code for this event can be found
in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the
Info Center for the appropriate user response.
806f000f-220201xx • 806f000f-220203xx
Appendix D. Integrated management module II (IMM2) error messages
451
Summary of Contents for System x3750 M4 Type 8733
Page 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Page 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 693: ......
Page 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...