W.3048006
[W.3048006] UEFI has booted from the backup flash bank due to an Automatic Boot Recovery (ABR)
event.
Explanation:
Automated Boot Recovery, Booting Backup UEFI Image
Severity:
Warning
User response:
Complete the following steps:
1.
Check IBM support site for an any service bulletins or firmware updates that apply to this error.
2.
Update the primary UEFI image. Refer to the section on recovering a UEFI image from an update failure to store
the system to the primary bank.
3.
Replace the system board.
W.305000A
[W.305000A] An invalid date and time have been detected.
Explanation:
RTC Date and Time Incorrect
Severity:
Warning
User response:
Complete the following steps:
1.
Check the IMM event log to see if this event is immediately preceded by an 68002 error or any other battery
related errors. If so, resolve those issues.
2.
Use F1 Setup to reset date and time. If problem returns after a system reset, replace the CMOS battery.
3.
If problem persists, check the IBM support site for an any service bulletins or firmware updates that apply to this
error.
4.
Replace the system board.
W.305800
[W.305800C] DRIVER HEALTH PROTOCOL: Reports 'System Shutdown' Required Controller.
Explanation:
A driver reported 'System Shutdown' required
Severity:
Warning
User response:
Complete the following steps:
1.
Shutdown and reboot the system.
W.3058009
[W.3058009] DRIVER HEALTH PROTOCOL: Missing Configuration. Requires Change Settings From
F1.
Explanation:
A driver reported missing configuration
Severity:
Warning
User response:
Complete the following steps:
1.
From the Setup utility, go to System Settings > Settings > Driver Health Status List and find a driver/controller
reporting Configuration Required status.
2.
Search for the driver menu from System Settings and change the settings appropriately.
3.
Save the settings and restart the system.
W.3048006 • W.3058009
Appendix A. UEFI/POST error codes
311
Summary of Contents for System x3750 M4 Type 8733
Page 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Page 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 693: ......
Page 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...