4.
Select
Add Boot Option
; then, select
Generic Boot Option
and
Embedded
Hypervisor
. Press Enter, and then press Esc.
5.
Select
Change Boot Order
and then select
Change the order
. Use the Up arrow
and Down Arrow keys to select
Embedded Hypervisor
and use the plus (+)
and minus (-) keys to move Embedded Hypervisor in the boot order. When
Embedded Hypervisor
is in the correct location in the boot order, press Enter.
Select
Commit Changes
and press Enter.
6.
Select
Save Settings
and then select
Exit Setup
.
If the embedded hypervisor flash device image becomes corrupted, you can
download the image from http://www.ibm.com/systems/x/os/vmware/esxi/.
For additional information and instructions, see the
VMware vSphere Installation and
Setup Guide
at http://pubs.vmware.com/vsphere-50/topic/com.vmware.ICbase/
PDF/vsphere-esxi-vcenter-server-50-installation-setup-guide.pdf.
Configuring the Ethernet controller
The Emulex BE3 Ethernet controller is integrated on the system board. It provides
an interface for connecting to a 1 Gbps or 10 Gbps network and provides
full-duplex (FDX) capability, which enables simultaneous transmission and
reception of data on the network. If the Ethernet ports in the server support
auto-negotiation, the controller detects the data-transfer rate (100BASE-T,
1000BASE-T, or 10GBASE-T) and duplex mode (full-duplex or half-duplex) of the
network and automatically operate at that rate and mode.
You do not have to set any jumpers or configure the controller. However, you must
install a device driver to enable the operating system to address the controller. For
device drivers and information about configuring the Ethernet controller, see
http://www.ibm.com/supportportal/.
Enabling Features on Demand Ethernet software
You can activate the Features on Demand (FoD) software upgrade key for Fibre
Channel over Ethernet (FCoE) and
i
SCSI storage protocols that is integrated in the
integrated management module. For more information and instructions for
activating the Features on Demand Ethernet software key, see the
IBM Features on
Demand User’s Guide
. To download the document, go to http://www.ibm.com/
systems/x/fod/, log in, and click
Help
.
Chapter 3. Configuration information and instructions
139
Summary of Contents for System x3750 M4 Type 8733
Page 1: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 138: ...122 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 164: ...148 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 210: ...194 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 220: ...204 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 303: ...SAS cable guide Adapter SAS signal cable Chapter 6 Removing and replacing components 287...
Page 306: ...4x2 5 inch backplane 290 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 308: ...8x2 5 inch backplane 292 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 310: ...294 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 312: ...296 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 332: ...316 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 672: ...656 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 676: ...660 System x3750 M4 Types 8722 and 8733 Installation and Service Guide...
Page 693: ......
Page 694: ...Part Number 90Y4479 Printed in USA 1P P N 90Y4479...