2.
You can order the one additional fan for redundant cooling.
3.
When more than 2 PCI-e adapters have been installed on the system, it is
necessary to follow the fan configuration instruction as the table below.
Table 5. Fan configuration instruction
Fans
Conditions
2 and
Rear
fan
Standard for all systems
3
1.
When the second microprocessor is populated, the fan is included in the
second microprocessor kit, P/N: 00D2581 ~ 00D2589. Or
2.
When more than 2 PCI-e adapters have been installed on the system, the fan
(P/N: 00D2593) will be available separately.
1
Optional redundant fan (P/N: 00D2593)
Attention:
When fan 3 is installed and 16 GB 1.5V / 32 GB 1.35V DIMMs are
installed, fan 1 must also be populated.
To install a simple-swap fan, complete the following steps:
1.
Read the safety information that begins on page “Safety” on page vii and
“Installation guidelines” on page 36.
2.
Turn off the server (see “Turning off the server” on page 24) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables as necessary to replace the device.
3.
Carefully turn the server on its side so that it is lying flat, with the cover facing
up.
Attention:
Do not allow the server to fall over.
4.
Unlock and remove the left-side cover (see “Removing the left-side cover” on
page 39).
Chapter 2. Installing optional devices
45
Summary of Contents for System x3300 M4
Page 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Page 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Page 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Page 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Page 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Page 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Page 405: ...Chapter 6 Removing and replacing components 387...
Page 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Page 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Page 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Page 469: ......
Page 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...