Table 19. DSA messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v
Go to the IBM support web site at http://www.ibm.com/supportportal/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component Test
State
Description
Action
215-901-xxx
Optical
Drive
v
Verify
Media
Installed
v
Read/
Write
Test
v
Self-Test
Messages
and actions
apply to all
three tests.
Aborted
Drive media is
not detected.
1.
Insert a CD/DVD into the DVD drive or
try a new media, and wait for 15 seconds.
2.
Run the test again.
3.
Check the drive cabling at both ends for
loose or broken connections or damage to
the cable. Replace the cable if it is
damaged.
4.
Run the test again.
5.
For additional troubleshooting
information, go to http://www.ibm.com/
support/docview.wss?uid=psg1MIGR-
41559.
6.
Run the test again.
7.
Replace the DVD drive.
8.
If the failure remains, go to the IBM Web
site for more troubleshooting information
at http://www.ibm.com/systems/
support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
215-902-xxx
Optical
Drive
v
Verify
Media
Installed
v
Read/
Write
Test
v
Self-Test
Messages
and actions
apply to all
three tests.
Failed
Read
miscompare.
1.
Insert a CD/DVD into the drive or try a
new media, and wait for 15 seconds.
2.
Run the test again.
3.
Check the drive cabling at both ends for
loose or broken connections or damage to
the cable. Replace the cable if it is
damaged.
4.
Run the test again.
5.
For additional troubleshooting
information, go to http://www.ibm.com/
support/docview.wss?uid=psg1MIGR-
41559.
6.
Run the test again.
7.
Replace the DVD drive.
8.
If the failure remains, go to the IBM Web
site for more troubleshooting information
at http://www.ibm.com/systems/
support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
Chapter 4. Troubleshooting
269
Summary of Contents for System x3300 M4
Page 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Page 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Page 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Page 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Page 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Page 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Page 405: ...Chapter 6 Removing and replacing components 387...
Page 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Page 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Page 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Page 469: ......
Page 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...