12.
Press the microprocessor 2 expansion board firmly and vertically to the
system board.
Note:
v
Static electricity that is released to internal server components when the
server is powered-on might cause the server to halt, which might result in
the loss of data. To avoid this potential problem, always use an
electrostatic-discharge wrist strap or other grounding system when you
work inside the server with the power on.
v
Make sure that none of the server cables are caught under the
microprocessor 2 expansion board.
13.
Rotate the release lever to the close position to secure the microprocessor 2
expansion board in place.
Note:
Press the microprocessor 2 expansion board connector to make sure the
connector is seated securely on the system board.
14.
Connect the microprocessor 2 power cable (P4) to its connector on the system
board (see“Power Cable Connection” on page 47 ).
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 104.
Installing a microprocessor and heat sink
Attention:
When you handle static-sensitive devices, take precautions to avoid
damage from static electricity. For details about handling these devices, see
“Handling static-sensitive devices” on page 39.
Notes:
v
If your server comes with one Intel Pentium 1400 series microprocessor, the
second microprocessor socket is not used. The server supports only one Intel
Pentium microprocessor. If you plan to install two Intel Xeon microprocessors in
the server, you must first remove the Intel Pentium microprocessor that came
with the server.
v
See “Installing a microprocessor and heat sink” for notes and other information
that you must consider when you install a microprocessor.
92
System x3300 M4 Type 7382: Installation and Service Guide
Summary of Contents for System x3300 M4
Page 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Page 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Page 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Page 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Page 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Page 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Page 405: ...Chapter 6 Removing and replacing components 387...
Page 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Page 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Page 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Page 469: ......
Page 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...