Table 18. IMM2 error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
80070301-0301xxxx
80070301-0302xxxx
Sensor CPU
n
OverTemp has
transitioned to
non-recoverable from
a less severe state. (
n
= microprocessor
number)
Error
A sensor has
changed to
non-recoverable
state from a less
severe state.
1.
Make sure that the fans are
operating, that there are no
obstructions to the airflow (front
and rear of the server), that the air
baffles are in place and correctly
installed, and that the server cover
is installed and completely closed.
2.
Check the ambient temperature. You
must be operating within the
specifications (see “Server features
and specifications” on page 6 for
more information).
3.
Make sure that the heat sink for
microprocessor
n
is installed
correctly (see “Replacing a
microprocessor and heat sink” on
page 418 for more information).
4.
(Trained technician only) Replace
microprocessor
n
(see “Removing a
microprocessor and heat sink” on
page 416 and “Replacing a
microprocessor and heat sink” on
page 418).
(
n
= microprocessor number)
8007021b-0301xxxx
8007021b-0302xxxx
Sensor CPU
n
QPI
link error has
transitioned to
critical from a less
severe state. (
n
=
microprocessor
number)
Error
A sensor has
changed to critical
state from a less
severe state.
1.
Remove cpu
2.
Check cpu socket pins, any damage
or contained or bending, replace the
system board.
3.
Check cpu damage, replace cpu.
Chapter 4. Troubleshooting
187
Summary of Contents for System x3300 M4
Page 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Page 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Page 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Page 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Page 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Page 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Page 405: ...Chapter 6 Removing and replacing components 387...
Page 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Page 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Page 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Page 469: ......
Page 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...