Table 18. IMM2 error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
80070608-0a01xxxx
80070608-0a02xxxx
Sensor PS
n
12V OC
Fault has
transitioned to
non-recoverable from
a less severe state. (
n
= power supply
number)
Error
A sensor has
changed to
non-recoverable
state from a less
severe state.
1.
Use the IBM Power Configurator
utility to determine current system
power consumption. For more
information and to download the
utility, go to http://www-
03.ibm.com/systems/bladecenter/
resources/powerconfig.html.
2.
For the hot-swap power-supply
systems, follow actions listed in
“Power problems” on page 289 and
“Solving power problems” on page
296.
3.
3. Replace the power supply.
80070608-0a01xxxx
80070608-0a02xxxx
Sensor PS
n
12V OV
Fault has
transitioned to
non-recoverable from
a less severe state. (
n
= power supply
number)
Error
A sensor has
changed to
non-recoverable
state from a less
severe state.
1.
Check power supply
n
LED.
2.
Remove the failing power supply.
3.
(Trained technician only) Replace
the system board.
(
n
= power supply number)
80070608-0a01xxxx
80070608-0a02xxxx
Sensor PS
n
12V UV
Fault has
transitioned to
non-recoverable from
a less severe state. (
n
= power supply
number)
Error
A sensor has
changed to
non-recoverable
state from a less
severe state.
1.
Check power supply
n
LED.
2.
Remove the failing power supply.
3.
For the hot-swap power-supply
systems, follow actions listed in
“Power problems” on page 289 and
“Solving power problems” on page
296.
(
n
= power supply number)
800b0008-1301xxxx
Power Unit has been
fully redundant.
Info
Power unit
redundancy has
been restored.
No action; information only.
800b0108-1301xxxx
Power Unit
redundancy lost has
asserted.
Error
Redundancy has
been lost and is
insufficient to
continue operation.
1.
Check the LEDs for both power
supplies.
2.
Follow the actions in “Power-supply
LEDs” on page 21.
806f0608-1301xx03
Power supply PS
Configuration error
with rating
mismatch.
Error
A power supply
configuration error
(rating mismatch)
has occurred.
1.
Make sure that the power supplies
installed are with the same rating or
wattage.
2.
Reinstall the power supplies with
the same rating or wattage.
Microprocessor messages
Chapter 4. Troubleshooting
181
Summary of Contents for System x3300 M4
Page 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Page 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Page 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Page 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Page 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Page 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Page 405: ...Chapter 6 Removing and replacing components 387...
Page 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Page 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Page 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Page 469: ......
Page 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...