Table 18. IMM2 error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f070c-2581xxxx
Memory DIMM
Configuration Error
for One of the
DIMMs.
Error
A memory DIMM
configuration error
has occurred.
Make sure that DIMMs are installed in
the correct sequence and have the same
size, type, speed, and technology.
806f070c-2581xxxx
Memory DIMM
Configuration Error
for All DIMMs.
Error
A memory DIMM
configuration error
has occurred.
Make sure that DIMMs are installed in
the correct sequence and have the same
size, type, speed, and technology.
806f090c-2001xxxx
806f090c-2002xxxx
806f090c-2003xxxx
806f090c-2004xxxx
806f090c-2005xxxx
806f090c-2006xxxx
806f090c-2007xxxx
806f090c-2008xxxx
806f090c-2009xxxx
806f090c-200axxxx
806f090c-200bxxxx
806f090c-200cxxxx
Memory DIMM for
DIMM
n
Status has
been automatically
throttled. (
n
= DIMM
number)
Warning
A memory DIMM
has been throttled.
1.
Reseat the DIMM, and then restart
the server.
2.
Replace DIMM
n
.
(
n
= DIMM number)
806f0a0c-2001xxxx
806f0a0c-2002xxxx
806f0a0c-2003xxxx
806f0a0c-2004xxxx
806f0a0c-2005xxxx
806f0a0c-2006xxxx
806f0a0c-2007xxxx
806f0a0c-2008xxxx
806f0a0c-2009xxxx
806f0a0c-200axxxx
806f0a0c-200bxxxx
806f0a0c-200cxxxx
An
Over-Temperature
condition has been
detected on the
DIMM
n
Status. (
n
=
DIMM number)
Error
An
over-temperature
condition has
occurred for
DIMM
n
. (
n
=
DIMM number)
1.
Make sure that the fans are
operating, that there are no
obstructions to the airflow, that the
air baffles are in place and correctly
installed, and that the server cover
is installed and completely closed.
2.
Make sure that ambient temperature
is within the specifications.
3.
If a fan has failed, complete the
action for a fan failure.
4.
Replace DIMM
n
.
(
n
= DIMM number)
800b010c-2581xxxx
Backup Memory
redundancy lost has
asserted.
Error
Redundancy has
been lost.
1.
Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup
utility.
800b030c-2581xxxx
Backup Memory
sufficient resources
from redundancy
degraded has
asserted.
Warning
There is no
redundancy. The
state has been
transitioned from
redundancy to
sufficient resources.
1.
Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup
utility.
800b050c-2581xxxx
Backup Memory
insufficient resources
has asserted.
Error
There is no
redundancy and
insufficient to
continue operation.
1.
Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup
utility.
Recovery messages
Chapter 4. Troubleshooting
199
Summary of Contents for System x3300 M4
Page 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Page 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Page 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Page 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Page 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Page 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Page 405: ...Chapter 6 Removing and replacing components 387...
Page 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Page 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Page 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Page 469: ......
Page 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...