v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Diagnostic
code
Message
Description
Action
I.1800F
[I.1800F] A processor family
mismatch has been detected for
one or more processor
packages.
Processors have mismatched
Family.
1.
Make sure that the microprocessor
is on the ServerProven website at
http://www.ibm.com/systems/
info/x86servers/serverproven/
compat/us/ .
2.
Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this problem.
3.
(Trained technician only) Remove
and replace the affected
microprocessor (error LED is lit)
with a supported type (see
“Replacing a microprocessor and
heat sink” on page 418).
I.18010
[I.18010] A processor stepping
mismatch has been detected for
one or more processor
packages.
Processors of the same model
have mismatched Stepping ID.
1.
Make sure that the microprocessor
is on the ServerProven website at
http://www.ibm.com/systems/
info/x86servers/serverproven/
compat/us/ .
2.
Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this problem.
3.
(Trained technician only) Remove
and replace the affected
microprocessor (error LED is lit)
with a supported type (see
“Replacing a microprocessor and
heat sink” on page 418).
160
System x3300 M4 Type 7382: Installation and Service Guide
Summary of Contents for System x3300 M4
Page 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Page 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Page 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Page 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Page 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Page 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Page 405: ...Chapter 6 Removing and replacing components 387...
Page 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Page 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Page 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Page 469: ......
Page 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...