Clearing CMOS data does not affect the administrator password.
Administrator password:
If an administrator password is set, you must type the administrator password for
access to the full Setup utility menu. You can use any combination of 6 to 20
printable ASCII characters for the password.
Attention:
If you set an administrator password and then forget it, there is no
way to change, override, or remove it. You must replace the system board.
Using the Boot Manager program
The Boot Manager program is a built-in, menu-driven configuration utility
program that you can use to temporarily redefine the first startup device without
changing settings in the Setup utility.
To use the Boot Manager program, complete the following steps:
1.
Turn off the server.
2.
Restart the server.
3.
When the prompt
<F12> Select Boot Device
is displayed, press F12. If a
bootable USB mass storage device is installed, a submenu item (
USB Key/Disk
)
is displayed.
4.
Use the Up arrow and Down arrow keys to select an item from the
Boot
Selection Menu
and press
Enter
.
The next time the server starts, it returns to the startup sequence that is set in the
Setup utility.
Starting the backup server firmware
The system board contains a backup copy area for the server firmware. This is a
secondary copy of the server firmware that you update only during the process of
updating the server firmware. If the primary copy of the server firmware becomes
damaged, use this backup copy.
To force the server to start from the backup copy, turn off the server; then, place
the UEFI Boot_backup jumper in the backup position (pins 2 and 3).
Use the backup copy of the server firmware until the primary copy is restored.
After the primary copy is restored, turn off the server; then, move the UEFI
Boot_backup jumper back to the primary position (pins 1 and 2).
122
System x3300 M4 Type 7382: Installation and Service Guide
Summary of Contents for System x3300 M4
Page 1: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3300 M4 Type 7382 Installation and Service Guide...
Page 8: ...vi System x3300 M4 Type 7382 Installation and Service Guide...
Page 18: ...xvi System x3300 M4 Type 7382 Installation and Service Guide...
Page 44: ...26 System x3300 M4 Type 7382 Installation and Service Guide...
Page 128: ...110 System x3300 M4 Type 7382 Installation and Service Guide...
Page 156: ...138 System x3300 M4 Type 7382 Installation and Service Guide...
Page 382: ...364 System x3300 M4 Type 7382 Installation and Service Guide...
Page 405: ...Chapter 6 Removing and replacing components 387...
Page 450: ...432 System x3300 M4 Type 7382 Installation and Service Guide...
Page 454: ...436 System x3300 M4 Type 7382 Installation and Service Guide...
Page 468: ...450 System x3300 M4 Type 7382 Installation and Service Guide...
Page 469: ......
Page 470: ...Part Number 00V9709 Printed in USA 1P P N 00V9709...