Table
21.
BMC
firmware
messages
(continued)
Message
Severity
Event
Automatic
Action
by
BMC
Action
required
by
user
Drive
bay
1,
hard
drive
(ModFD
Error)
fault
Error
A
fault
has
occurred
with
the
modular
flash
drive.
Remove
and
reseat
the
modular
flash
drive.
Reboot.If
the
error
condition
continues,
replace
the
modular
flash
drive
with
a
similar
unit
and
reboot.If
this
does
not
correct
the
problem,
contact
IBM
service.
Firmware
progress
events
FW/BIOS,
firmware
progress
(Pri
FW
Corrupt)
system
board
hang
Error
An
error
has
occurred
on
the
system
board
during
boot.
Blade
reboots
If
the
error
persists,
contact
IBM
service.
FW/BIOS,
firmware
progress
(Pri
FW
Corrupt)
no
system
memory
Error
No
system
memory
was
found
Blade
does
not
power
on
Add
system
memory,
or
reseat
existing
system
memory.
Reboot.
FW/BIOS,
firmware
progress
(Pri
FW
Corrupt)
no
usable
system
memory
Error
System
memory
was
found,
but
is
unusable
Blade
does
not
power
on
Check
supported
memory
configurations.
See
“Adding
or
changing
system
memory”
on
page
39
for
further
information.
Memory
subsystem
Memory
device
x
(DIMM
x
uncorrectable
ECC
memory
errorwhere
x
is
the
number
of
the
affected
DIMM.
Error
A
system
DIMM
or
an
I/O
buffer
DIMM
has
returned
an
uncorrectable
error.
The
affected
memory
channel
is
disabled.
If
the
error
concerns
and
I/O
buffer
DIMM,
both
I/O
buffer
DIMMs
are
disabled.
Replace
the
affected
DIMM.
If
the
problem
continues,
contact
IBM
service.
Memory
device
x
(DIMM
x
memory
disabledwhere
x
is
the
number
of
the
affected
DIMM.
Error
A
system
DIMM
or
an
I/O
buffer
DIMM
has
returned
an
uncorrectable
error.
The
affected
memory
channel
is
disabled.
If
the
error
concerns
and
I/O
buffer
DIMM,
both
I/O
buffer
DIMMs
are
disabled.
Chapter
5.
Diagnostics
and
troubleshooting
105
Summary of Contents for QS22 - BladeCenter - 0793
Page 1: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 8: ...Index 135 vi BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 44: ...26 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 72: ...54 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 156: ...138 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 157: ......
Page 158: ...Part Number 44R5162 1P P N 44R5162...