DSA
error
messages
The
tables
below
describe
the
messages
that
the
diagnostic
programs
might
generate
and
suggested
actions
to
correct
the
detected
problems.
Follow
the
suggested
actions
in
the
order
given.
CPU
test
results
Table
6.
CPU
test
results
Test
Number
Status
Extended
results
Actions
CPU
stress
test
089-901-
xxx
Fail
Test
failure
1.
If
the
system
has
stopped
responding,
turn
off
and
restart
the
system
and
then
run
the
test
again.
2.
Make
sure
that
the
DSA
Diagnostic
code
is
at
the
latest
level.
The
latest
level
DSA
Diagnostic
code
can
be
found
on
the
IBM
Support
Web
site
at
http://www.ibm.com/
support/docview.wss?uid=psg1SERV-DSA/.
3.
Run
the
test
again.
4.
Check
system
firmware
level
and
upgrade
if
necessary.
The
installed
firmware
level
can
be
found
in
the
DSA
Diagnostic
Event
Log
within
the
Firmware/VPD
section
for
this
component.
The
latest
level
firmware
for
this
component
can
be
found
on
the
IBM
Support
Web
site
athttp://www.ibm.com/support/us/en/.
5.
Run
the
test
again.
6.
If
the
system
has
stopped
responding,
turn
off
and
restart
the
system
and
then
run
the
test
again.
7.
If
the
test
continues
to
fail,
refer
to
the
other
sections
of
this
chapter
for
diagnosis
and
corrective
action.
089-802-
xxx
Abort
System
resource
availability
error
089-801-
xxx
Abort
Internal
program
error
BMC
test
results
Table
7.
BMC
test
results
Test
Number
Status
Extended
results
Actions
I2C
test
166-901-
xxx
Fail
The
BMC
indicates
a
failure
in
the
IPMB
bus.
1.
Turn
off
the
system
and
disconnect
it
from
power.
The
system
must
be
removed
from
AC
power
in
order
to
reset
the
BMC.
2.
After
45
seconds,
reconnect
the
system
to
power
and
turn
on
the
system.
3.
Run
the
test
again.
4.
Make
sure
that
the
DSA
Diagnostic
code
is
at
the
latest
level.
The
latest
level
DSA
Diagnostic
code
can
be
found
on
the
IBM
Support
Web
site
at
http://www.ibm.com/
support/docview.wss?uid=psg1SERV-DSA/.
5.
Check
BMC
firmware
level
and
upgrade
if
necessary.
The
installed
firmware
level
can
be
found
in
the
DSA
Diagnostic
Event
Log
within
the
Firmware/VPD
section
for
this
component.
The
latest
level
firmware
for
this
component
can
be
found
on
the
IBM
Support
Web
site
athttp://www.ibm.com/support/us/en/.
6.
Run
the
test
again.
7.
If
the
test
continues
to
fail,
refer
to
the
other
sections
of
this
chapter
for
diagnosis
and
corrective
action.
Chapter
5.
Diagnostics
and
troubleshooting
69
Summary of Contents for QS22 - BladeCenter - 0793
Page 1: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 8: ...Index 135 vi BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 44: ...26 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 72: ...54 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 156: ...138 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 157: ......
Page 158: ...Part Number 44R5162 1P P N 44R5162...