Adding
or
changing
I/O
buffer
DDR2
memory
modules
This
section
describes
how
to
add
I/O
buffer
memory.
For
instructions
on
how
to
add
system
memory
see
“Adding
or
changing
system
memory”
on
page
39.
Each
IBM
PowerXCell
8i
companion
chip
has
one
DIMM
slot
for
I/O
buffer
memory.
The
QS22
blade
server
supports
VLP
DDR2
1
GB
DIMMs.
You
must
add
memory
as
a
pair
of
DIMMs,
one
for
each
IBM
PowerXCell
8i
companion
chip.
To
install
I/O
buffer
memory,
complete
the
following
steps:
1.
Read
the
safety
information
beginning
on
page
vii
and
“Installation
guidelines”
on
page
29.
2.
If
applicable,
shut
down
the
operating
system,
turn
off
the
blade
server,
and
remove
the
blade
server
from
the
BladeCenter
unit.
See
“Removing
the
blade
server
from
the
BladeCenter
unit”
on
page
30.
3.
Open
the
blade
server
cover.
See
“Opening
and
removing
the
blade
server
cover”
on
page
31.
4.
Locate
the
DIMM
slots
for
the
I/O
buffer
DDR2
memory
modules.
There
are
two
DIMM
slots,
one
for
each
IBM
PowerXCell
8i
companion
chip.
The
slots
are
labelled
IOBUF
1
and
IOBUF
2
.
You
must
install
a
1
GB
DIMM
for
both
IBM
PowerXCell
8i
companion
chips.
5.
Remove
the
DIMM
fillers
from
the
slots.
Retain
the
DIMM
fillers.
They
are
an
important
part
of
the
blade
server
cooling
system
and
you
need
them
if
you
ever
remove
the
I/O
buffer
DIMMs
from
the
blade
server.
6.
If
applicable,
remove
any
modules
that
are
to
be
replaced
or
that
have
become
redundant.
a.
Open
the
retaining
clips
on
either
end
of
the
DIMM
slot.
This
lifts
the
DIMM
and
disengages
it
from
the
slot.
b.
Pull
the
DIMM
out
of
the
slot.
7.
Place
each
DIMM
in
its
slot,
contact
side
down.
Check
the
orientation
of
the
modules.
The
locating
pin
in
each
slot
must
match
the
corresponding
cut-out
on
the
module.
8.
Carefully
press
the
modules
into
place
until
the
retaining
clips
snap
into
place.
Make
sure
that
the
clips
are
locked
properly.
Figure
16.
I/O
buffer
DIMM
slot
location
Chapter
4.
Installing
and
removing
replaceable
units
41
Summary of Contents for QS22 - BladeCenter - 0793
Page 1: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 8: ...Index 135 vi BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 44: ...26 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 72: ...54 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 156: ...138 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 157: ......
Page 158: ...Part Number 44R5162 1P P N 44R5162...