Table
12.
DIMM
boot
errors
(continued)
Code
Message
Description
Action
W1400
Memory
hole
between
physical
address
x
and
y
Memory
hole.
Due
to
error
E1100
a
portion
of
the
predetermined
physical
address
map
(configuration
ring)
is
unavailable,
leaving
a
memory
hole
in
the
address
map.
Replace
the
DIMM
where
the
error
occurred
with
a
supported
DIMM.
See
Chapter
3,
“Parts
listing,”
on
page
27
for
details
of
supported
DIMMs.
E1500
Bad
memory
configuration.
Aborting
system
boot
Bad
configuration.
Due
to
occurrences
of
errors
E1100,
E1120,
E1140,
E1150
the
BMC
cannot
power
on
the
system.
Check
DIMM
configuration
and
correct
where
necessary.
See
“Adding
or
changing
system
memory”
on
page
39
for
details
of
permitted
configurations.
W1700
Multiple
attempts
needed
to
reset
DQS
latches
on
CPUx.
DQS
reset
problems.
Firmware
needed
multiple
attempts
to
ensure
that
the
DQS
latches
were
properly
put
in
reset.
IBM
PowerXCell
8i
informational
message
W1800
Unable
to
reset
DQS
latches
on
CPUx.
DQS
reset
error.
Firmware
exceeded
maximum
attempts
to
ensure
that
the
DQS
latches
were
properly
put
in
reset.
IBM
PowerXCell
8i
informational
message
USB
errors
The
following
table
describes
boot
list
errors.
These
may
occur
when
booting
from
a
bootable
CD
or
DVD.
Table
13.
System
firmware
boot
errors
Code
Message
Description
Action
E5000
(USB)
Media
or
drive
not
ready
for
this
blade.
The
media
tray
is
not
accessible
for
boot.
Verify
that
the
media
tray
is
assigned
to
the
blade
and
that
the
media
is
configured
correctly.
If
this
does
not
resolve
the
problem,
check
the
other
blade
servers.
If
they
cannot
access
the
media,
there
may
be
a
problem
with
the
BladeCenter
unit.
See
the
documentation
that
comes
with
the
BladeCenter
unit
for
further
information.
E5010
(USB)
No
Media
Found!
Please
check
for
the
drawer/inserted
media.
Media
is
not
inserted
or
the
drawer
of
the
media
tray
is
open.
Ensure
that
there
is
a
bootable
CD
or
DVD
in
the
tray
and
that
the
drawer
is
closed.
E5020
(USB)
Unknown
media
format.
The
media
is
not
recognized
by
the
firmware.
Insert
a
suitable
bootable
CD.
Chapter
5.
Diagnostics
and
troubleshooting
83
Summary of Contents for QS22 - BladeCenter - 0793
Page 1: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 8: ...Index 135 vi BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 44: ...26 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 72: ...54 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 156: ...138 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 157: ......
Page 158: ...Part Number 44R5162 1P P N 44R5162...