Code
Message
Description
Action
E4010
Platform
check
failed
for
image
The
firmware
image
does
not
match
the
hardware
platform.
Check
the
firmware
image
and
ensure
you
have
the
right
image
for
the
BladeCenter
QS22.
See
“Using
the
SMS
utility
program”
on
page
11.
If
the
image
is
incorrect,
download
and
install
the
correct
image
from
http://www.ibm.com/support/us/en/.
See
“Updating
the
system
and
BMC
firmware”
on
page
15
for
further
information.
E4020
(RTAS
flash)
image
corrupted
(CRC)
The
image
for
a
system
firmware
update
is
corrupted.
Download
the
image
again
and
reapply
the
update.
If
this
does
not
resolve
the
problem,
apply
an
image
from
a
different
source.
System
memory
errors
The
following
table
describes
system
memory
initialization
errors
that
can
occur
during
boot.
Table
12.
DIMM
boot
errors
Code
Message
Description
Action
E1100
Incompatible
DIMM
in
slot
x
.
Disabling
slots
x
and
y
.
where
x
is
the
slot
containing
the
incompatible
DIMM
and
y
is
the
slot
containing
its
pair.
Incompatible
DIMM.
DIMM
does
not
match
technical
requirements
of
the
memory
controller.
Note:
Both
the
offending
DIMM
and
its
pair
are
disabled.
System
DIMM
must
operate
in
pairs.
Replace
the
DIMM
with
a
supported
DIMM.
See
Chapter
3,
“Parts
listing,”
on
page
27
for
details
of
supported
DIMMs.
W1110
Unsupported
DIMM
in
slot
x
.
where
x
is
the
slot
containing
the
unsupported
DIMM.
Unsupported
DIMM.
DIMM
is
within
technical
requirements
of
memory
controller
but
is
untested.
Replace
the
DIMM
with
a
supported
DIMM.
See
Chapter
3,
“Parts
listing,”
on
page
27
for
details
of
supported
DIMMs.
E1120
Unsupported
plugging:
No
pair
in
slots
x
and
y.
Disabling
slots.
where
x
and
y
form
the
pair
of
slots
on
a
given
channel.
Plugging
rule
violation.
No
pair
plugged
on
a
given
channel.
Check
DIMM
configuration.
See
“Adding
or
changing
system
memory”
on
page
39for
details
of
permitted
configurations.
W1130
Unsupported
plugging.
This
message
appears
with
one
of
the
following
informational
messages:
Plugging
sequence
violation.
DIMMs
are
not
plugged
in
supported
sequence
Check
DIMM
configuration.
See
“Adding
or
changing
system
memory”
on
page
39
details
of
permitted
configurations.
80
BladeCenter
QS22
Type
0793:
Problem
Determination
and
Service
Guide
Summary of Contents for QS22 - BladeCenter - 0793
Page 1: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 8: ...Index 135 vi BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 44: ...26 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 72: ...54 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 156: ...138 BladeCenter QS22 Type 0793 Problem Determination and Service Guide...
Page 157: ......
Page 158: ...Part Number 44R5162 1P P N 44R5162...