256D-701
Explanation:
Error Log Analysis indicates permanent adapter failure.
1.
Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board
Response:
Failing Item:
v
v
256D-702
Explanation:
Error Log Analysis indicates permanent adapter failure is reported on the other port of this adapter.
1.
Check the BladeCenter management-module event log. If an error was recorded by the system, see POST progress
codes (checkpoints).
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board
Response:
Failing Item:
v
v
25C4-201
Explanation:
Configuration error. Go to Performing the checkout procedure.
Response:
Failing Item:
v
25C4-601
Explanation:
Download firmware error. Go to Performing the checkout procedure.
Response:
Failing Item:
v
256D-701 • 25C4-601
Chapter 8. Troubleshooting
325
Summary of Contents for Flex System p270 Compute Node
Page 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 509: ...Appendix Notices 497 ...
Page 510: ...IBM Printed in USA ...