CA279001
Explanation:
The firmware update image contains an update module that is not already on the system.
Response:
1.
Look at the event log for a BA27xxxx error code to determine if a firmware installation error occurred.
2.
If a firmware installation error did occur, resolve the problem.
3.
Retry the firmware update.
4.
If the problem persists:
a.
b.
Replace the system-board, as described in Replacing the system-board and chassis assembly.
CA2799FD
Explanation:
A firmware update module is being read.
Response:
This checkpoint alternates in the control panel with CA2799FF.
This pair of checkpoints might stay in the display for up to 30 minutes with no indication of activity other than the
alternating codes. Do not assume that the system is hung until the alternation stops and only one of the checkpoints
remains in the control panel for at least 30 minutes, with no other indication of activity.
If the system is hung on this checkpoint, then CA2799FD and CA2799FF are not alternating and you must perform
the following procedure:
1.
Shut down the server.
2.
Restart the server using the permanent boot image, as described in Starting the PERM image.
3.
Use the Update and Manage System Flash menu to reject the temporary image.
CA2799FF
Explanation:
A firmware update module is being written.
Response:
This checkpoint alternates in the control panel with CA2799FD.
This pair of checkpoints might stay in the display for up to 30 minutes with no indication of activity other than the
alternating codes. Do not assume that the system is hung until the alternation stops and only one of the checkpoints
remains in the control panel for at least 30 minutes, with no other indication of activity. If the system is hung on this
checkpoint, then CA2799FD and CA2799FF are not alternating and you must perform the following procedure:
1.
Shut down the server.
2.
Restart the server using the permanent boot image, as described in Starting the PERM image.
3.
Use the Update and Manage System Flash menu to reject the temporary image.
CA279001 • CA2799FF
Chapter 8. Troubleshooting
279
Summary of Contents for Flex System p270 Compute Node
Page 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 509: ...Appendix Notices 497 ...
Page 510: ...IBM Printed in USA ...