26D7-118
Explanation:
A SCSI command time-out occurred. Replace the 900 GB SFF SAS Hard Disk Drive. Run diagnostics
again on the drive. If the error repeats, replace the 2nd FRU identified by diagnostics.
Response:
Failing Item:
v
v
26D7-120
Explanation:
A SCSI busy or command error. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v
26D7-122
Explanation:
A SCSI reservation conflict error. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v
26D7-124
Explanation:
A SCSI check condition error occurred. Replace the 900 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v
26D7-126
Explanation:
A software error was caused by a hardware failure. Replace the 900 GB SFF SAS Hard Disk Drive. Run
diagnostics again on the drive. If the error repeats, replace the 2nd FRU identified by diagnostics.
Response:
Failing Item:
v
v
26D7-118 • 26D7-126
360
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide
Summary of Contents for Flex System p270 Compute Node
Page 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 509: ...Appendix Notices 497 ...
Page 510: ...IBM Printed in USA ...