11002901
Explanation:
SSD interposer card pGood fault on the base system board.
Response:
1.
Replace the interposer card on the base system board.
11002902
Explanation:
SSD drive power-on self-test failure on the base system board
Response:
Perform one of the following:
v
Replace the first SSD drive on the base system board.
v
Replace the second SSD drive on the base system board.
11002910
Explanation:
SSD drive or SSD interposer card 3.3V pGood fault on the expansion system board.
Response:
1.
Replace the following, one at a time, until the failure is no longer detected:
a.
The SSD interposer card on the expansion system board
b.
The first SSD drive on the expansion system board
c.
The second SSD drive on the expansion system board
11002911
Explanation:
SSD interposer card pGood fault on the expansion system board
Response:
1.
Replace the interposer card on the expansion system board.
11002912
Explanation:
SSD drive power-on self-test failure.
Response:
Perform one of the following:
v
Replace the first SSD drive on the expansion system board.
v
Replace the second SSD drive on the expansion system board.
11003118
Explanation:
Thermal sensor read error.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
If this is an IBM Flex System p260 or p24L compute node, replace the light path diagnostics panel. If this is an
IBM Flex System p460 compute node, check word 3 of the SRC. If word 3 is 00003100, the thermal sensor in the
first bay is failing; replace the light path diagnostics panel. If word 3 is 00003101, the thermal sensor in the second
bay is failing; replace the thermal sensor in the second bay of the compute node. For all other servers, replace the
system board. If there is more than one system board, use the location code in the SRC to identify which system
board to replace.
11002901 • 11003118
Chapter 8. Troubleshooting
117
Summary of Contents for Flex System p270 Compute Node
Page 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 509: ...Appendix Notices 497 ...
Page 510: ...IBM Printed in USA ...