2.
See “Failing function codes” on page 437 for a description of each FFC value.
3.
If the SRN does not appear in the table, see “Solving undetermined problems” on page 484.
4.
After replacing a component, verify the replacement part and perform a log-repair action using the
AIX diagnostics.
101-711 through FFC-725 SRNs:
The AIX operating system might generate service request numbers (SRNs) from 101-711 to FFC-725.
Replace any parts in the order that the codes are listed.
101-711
Explanation:
The system hung while trying to configure an unknown resource.
1.
Run the stand-alone diagnostics problem determination procedure.
2.
If the problem remains, refer to Failing function codes to find the FFC that matches the last three digits of the
SRN.
3.
Suspect the device adapter or device itself.
Response:
Failing Item:
v
101-712
Explanation:
The system hung while trying to configure an unknown resource.
1.
Run the stand-alone diagnostics problem determination procedure.
2.
If the problem remains, refer to Failing function codes to find the FFC that matches the last three digits of the
SRN.
3.
Suspect the device adapter or device itself.
Response:
Failing Item:
v
101-713
Explanation:
The system hung while trying to configure an unknown resource.
1.
Run the stand-alone diagnostics problem determination procedure.
2.
If the problem remains, refer to Failing function codes to find the FFC that matches the last three digits of the
SRN.
3.
Suspect the device adapter or device itself.
Response:
Failing Item:
v
101-711 • 101-713
Chapter 8. Troubleshooting
293
Summary of Contents for Flex System p270 Compute Node
Page 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 509: ...Appendix Notices 497 ...