B2003114
Explanation:
A problem occurred during the startup of a partition.
Response:
Look for other errors and resolve them.
B2003120
Explanation:
Informational system log entry only.
Response:
No corrective action is required.
B2003123
Explanation:
Informational system log entry only.
Response:
No corrective action is required.
B2003125
Explanation:
During the startup of a partition, the server firmware could not obtain a segment of main storage
within the server to use for managing the creation of a partition.
Response:
Check for server firmware updates; then, install the updates if available.
B2003128
Explanation:
A problem occurred during the startup of a partition. A return code for an unexpected failure was
returned when attempting to query the load source path.
Response:
Look for and resolve B700 69xx errors.
B2003130
Explanation:
A problem occurred during the startup of a partition.
Response:
Check for server firmware updates; then, install the updates if available.
B2003135
Explanation:
A problem occurred during the startup of a partition.
Response:
Check for server firmware updates; then, install the updates if available.
B2003140
Explanation:
A problem occurred during the startup of a partition. This is a configuration problem in the partition.
Response:
Reconfigure the partition to include the intended load source path.
B2003114 • B2003140
144
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide
Summary of Contents for Flex System p270 Compute Node
Page 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 509: ...Appendix Notices 497 ...
Page 510: ...IBM Printed in USA ...