BA210101
Explanation:
The partition firmware event log queue is full
Response:
1.
Reboot the server.
2.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA210102
Explanation:
There was a communication failure between partition firmware and the hypervisor. The lpevent that
was expected from the hypervisor was not received.
Response:
1.
Review the event log for errors that occurred around the time of this error.
2.
Correct any errors that are found and reboot the server.
3.
If the problem persists, Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA210103
Explanation:
There was a communication failure between partition firmware and the hypervisor. There was a failing
return code with the lpevent acknowledgement from the hypervisor.
Response:
1.
Review the event log for errors that occurred around the time of this error.
2.
Correct any errors that are found and reboot the server.
3.
If the problem persists, Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA220010
Explanation:
There was a partition firmware error during USB hotplug probing. USB hotplug may not work
properly on this partition.
Response:
1.
Review the event log for EEH-type errors that occurred around the time of this error.
2.
Correct any EEH errors that are found and reboot the server.
3.
If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
BA210101 • BA220010
216
Power Systems: IBM Flex System p270 Compute Node Installation and Service Guide
Summary of Contents for Flex System p270 Compute Node
Page 1: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p270 Compute Node Installation and Service Guide IBM ...
Page 38: ...26 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 40: ...28 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 110: ...98 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 498: ...486 Power Systems IBM Flex System p270 Compute Node Installation and Service Guide ...
Page 509: ...Appendix Notices 497 ...
Page 510: ...IBM Printed in USA ...