Power Fault Message in
the System Error Log
Failing FRU/Action
5V bus A
(Power to PCI, I/O, NIO and
CPU complex)
1. Remove AC power.
2. Reduce the system to
one processor
daughter board with
one processor.
3. Remove the cache
coherency filter
DIMMs.
4. Remove all PCI
adapters except the
I\O function card and
the system
management adapter.
5. Reconnect the AC
power and wait about
30 seconds for the
system management
adapter to initialize.
6. Attempt to start the
system. If the system
starts, one of the FRUs
removed is the failing
FRU. Reinstall the
FRUs one at a time to
identify the failing FRU.
7. If the system does not
start, suspect
remaining system
FRUs in the following
order:
a. Hotswap sense
card
b. I/O function card
c. System
management
adapter
d. I/O board
e. Processor
f. Processor
daughter board
g. Processor board
h. Power control
card
i. Midplane
j. Power supply
Netfinity 8500R - Type 8681
179
Summary of Contents for 8500R - Netfinity - 8681
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 25: ...1 LVD low voltage differential Netfinity 8500R Type 8681 17...
Page 62: ...Caution Use safe practices when lifting 54 Netfinity Server HMM...
Page 242: ...I O Housing Assembly 1 2 3 4 5 6 7 234 Netfinity Server HMM...
Page 261: ...Related service information 253...
Page 262: ...254 Netfinity Server HMM...
Page 263: ...Related service information 255...
Page 264: ...256 Netfinity Server HMM...
Page 265: ...Related service information 257...
Page 278: ...270 Netfinity Server HMM...
Page 279: ...Related service information 271...
Page 280: ...272 Netfinity Server HMM...
Page 290: ...IBM Part Number 37L5123 Printed in U S A S37L 5123...