AC LED on/DC LED off:
If the AC LED is on and
the DC LED is off, do the following:
1. Check the Power Control Card LED, then return to
this table. See “Power control card LED” on
page 176).
2. Attempt to start the system and check the DC Good
LEDs.
3. If the Good AC LED on and DC Good LED off
condition does not exist on all power supplies, move
the power supply with the DC Good LED off to one of
the other power supply positions. If the DC Good
LED off condition stays with the power supply,
replace FRUs in the following order:
a. Power supply
b. Power control card
c. Midplane
If the DC Good LED off condition stays with the
power supply position, replace FRUs in the following
order, then go to step 10 on page 175:
a. Power control card
b. Midplane
4. If the condition exists on all the power supplies,
disconnect the AC power from all supplies for 30
seconds, then reconnect AC power and attempt to
start the system. Check the LEDs again. If DC Good
LEDs are lit on all power supplies, continue with
system checkout. If not, continue with step 5.
5. Disconnect the ac power and reduce the system to
the minimum configuration described in the note at
the beginning of this section.
6. Install a jumper on J11 on the I/O Board (see “I/O
board component locations” on page 116).
7. Connect the AC power cord and attempt to start the
system. Check the DC Good LED.
8. If the DC Good LED is on, reinstall the components in
the following order to isolate the failing FRU:
a. I/O Function Card
b. Front Panel (once installed, jumper J11 on the
I/O board is no longer needed).
c. System management adapter
d. All remaining components, one at a time.
9. If the DC Good LED is off, swap power supplies. If
the DC Good LED is still off, replace FRUs in the
following order, then go to step 10 on page 175:
a. Power control card
b. Midplane
Table 15 (Page 2 of 2). Power Supply LED Errors
AC
Good
LED
DC
Good
LED
Error
FRU/Action
On
On
Power
is OK
None
174
Netfinity Server HMM
Summary of Contents for 8500R - Netfinity - 8681
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 25: ...1 LVD low voltage differential Netfinity 8500R Type 8681 17...
Page 62: ...Caution Use safe practices when lifting 54 Netfinity Server HMM...
Page 242: ...I O Housing Assembly 1 2 3 4 5 6 7 234 Netfinity Server HMM...
Page 261: ...Related service information 253...
Page 262: ...254 Netfinity Server HMM...
Page 263: ...Related service information 255...
Page 264: ...256 Netfinity Server HMM...
Page 265: ...Related service information 257...
Page 278: ...270 Netfinity Server HMM...
Page 279: ...Related service information 271...
Page 280: ...272 Netfinity Server HMM...
Page 290: ...IBM Part Number 37L5123 Printed in U S A S37L 5123...