Attention
To avoid breaking the retaining clips or damaging
the DIMM connectors, handle the clips gently.
5. Install the DIMM:
a. Turn the DIMM
.3/
so that the keys align
correctly with the connector.
b. Align the keyed DIMM
.3/
, and press on both
sides of the DIMM as you insert it into the
connector. Be sure to press the DIMM straight
into the connector.
Note
If a gap exists between the DIMM and the
retaining clips, the DIMM has not been
properly installed. Open the retaining clips
and remove the DIMM; then, reinsert the
DIMM.
c. Make sure that the retaining clips
.2/
are in the
closed position.
d. Repeat these steps for each DIMM that you
install.
6. Reinstall the memory board:
a. Insert the memory board into the guides and
gently press the memory board into the
connector. When you install the memory board
in the server, be sure that it is correctly seated in
the connector before you apply force to close the
latches.
b. Push the latches
.1/
until they close and lock in
place.
Attention
To ensure proper EMC containment and
cooling for the server, reinstall the
memory-access panel before turning on the
server.
c. Reinstall the memory-access panel:
1) Ensure that the memory-access panel is
fully seated in the appropriate location.
2) Press in the two plastic fasteners on the
memory-access panel to secure it into
place.
d. Reinstall the front bezel (see “Installing the front
bezel” on page 58).
7. If you have other options to install or remove, do so
now; otherwise, continue with “Completing the
installation” on page 56.
68
Netfinity Server HMM
Summary of Contents for 8500R - Netfinity - 8681
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 25: ...1 LVD low voltage differential Netfinity 8500R Type 8681 17...
Page 62: ...Caution Use safe practices when lifting 54 Netfinity Server HMM...
Page 242: ...I O Housing Assembly 1 2 3 4 5 6 7 234 Netfinity Server HMM...
Page 261: ...Related service information 253...
Page 262: ...254 Netfinity Server HMM...
Page 263: ...Related service information 255...
Page 264: ...256 Netfinity Server HMM...
Page 265: ...Related service information 257...
Page 278: ...270 Netfinity Server HMM...
Page 279: ...Related service information 271...
Page 280: ...272 Netfinity Server HMM...
Page 290: ...IBM Part Number 37L5123 Printed in U S A S37L 5123...