Attention
1. Before you hot-swap a drive, refer to the amber
hard-disk status light for that drive to make sure
that it is defective. If the server has a
ServeRAID adapter installed and you assigned
RAID level 1 or 5 to the logical drives in the disk
array, make sure that the drive is defective. If
you partially or completely remove a good drive
instead of a defective one, the server might lose
valuable data. However, the ServeRAID adapter
can rebuild the data that you need, provided that
certain conditions are met. Refer to the
ServeRAID adapter documentation for further
details.
2. To avoid damage to a hard disk drive,
do not
remove the drive from the hot-swap bay until it
has had time to spin down (approximately 30
seconds after disconnecting). Handle the drive
gently.
Before you begin:
Read “Safety information” on page 240.
Read the documentation that comes with the
drive.
Refer to the following illustration while you perform the
steps in this procedure.
.1/
Filler panel (tray and slim filler bezel)
.2/
Hot-swap hard disk drive
.3/
Drive tray handle (open position)
To install or replace a hard disk drive:
1. Determine the bay in which you want to install the
drive. Otherwise, continue with step 2 on page 115.
Remove the defective hard disk drive
.2/
by pressing
on the lock to release the handle
.3/
, placing the
handle in the open position (perpendicular to the
drive), and pulling the hot-swap tray from the bay.
Continue with step 3 on page 115.
114
Netfinity Server HMM
Summary of Contents for 8500R - Netfinity - 8681
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 25: ...1 LVD low voltage differential Netfinity 8500R Type 8681 17...
Page 62: ...Caution Use safe practices when lifting 54 Netfinity Server HMM...
Page 242: ...I O Housing Assembly 1 2 3 4 5 6 7 234 Netfinity Server HMM...
Page 261: ...Related service information 253...
Page 262: ...254 Netfinity Server HMM...
Page 263: ...Related service information 255...
Page 264: ...256 Netfinity Server HMM...
Page 265: ...Related service information 257...
Page 278: ...270 Netfinity Server HMM...
Page 279: ...Related service information 271...
Page 280: ...272 Netfinity Server HMM...
Page 290: ...IBM Part Number 37L5123 Printed in U S A S37L 5123...