SMI Error
Message
FRU/Action
Error on Processor
Bn
Suspect FRUs in the following order:
1. Processor Bn
2. Run diagnostics on the processors
3. Processor daughter board B
4. Processor controller board
P6 I/O bus UNC
error
If message "UNC Error on PCI bus slot x" is
also displayed, follow the FRU/Action for that
message first, then suspect FRUs in the
following order:
1. I/O board
2. Processor controller board
UNC Error on PCI
bus M
Suspect FRUs in the following order:
1. Any PCI adapters on bus M (including
I/O Function card or System
Management Adapter for bus A)
2. System management adapter cable
3. I/O board
P6 I/O Bus Hard
Failure Response
(HFR)
Reinstall the device driver for the last PCI
adapter installed, then suspect FRUs in the
following order:
1. The last installed PCI adapter
2. Any other PCI adapter
3. System Management Adapter
4. I/O Function card
5. I/O board
UNC Error on PCI
bus slot x
Suspect FRUs in the following order:
1. PCI adapter in slot x
2. I/O board
3. Another adapter on the same PCI bus
Address Parity
Error (APE) on PCI
bus M
Suspect FRUs in the following order:
1. Any PCI adapters on bus M (including
I/O function card or System Management
Adapter for bus A)
2. System management adapter cable
3. I/O board
SBC error on P6
Process Bus A
Suspect FRUs in the following order:
1. Run diagnostics on the processors
2. Any processor on bus A
3. Processor daughter board A
4. Processor controller board
SBC error on P6
Process Bus B
Suspect FRUs in the following order:
1. Run diagnostics on the processors
2. Any processor on bus B
3. Processor daughter board B
4. Processor controller board
SBC error on P6
I/O bus
Suspect FRUs in the following order:
1. I/O board
2. Processor controller board
Uncorrectable MCA
error
Suspect any processor on bus A and B
1. Run diagnostics on the processors
Correctable MCA
error
Suspect any processor on bus A and B
1. Run diagnostics on the processors
SBC Memory error
has occurred
Suspect any DIMM on memory bus A and B
1. Run diagnostics on the memory
228
Netfinity Server HMM
Summary of Contents for 8500R - Netfinity - 8681
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 25: ...1 LVD low voltage differential Netfinity 8500R Type 8681 17...
Page 62: ...Caution Use safe practices when lifting 54 Netfinity Server HMM...
Page 242: ...I O Housing Assembly 1 2 3 4 5 6 7 234 Netfinity Server HMM...
Page 261: ...Related service information 253...
Page 262: ...254 Netfinity Server HMM...
Page 263: ...Related service information 255...
Page 264: ...256 Netfinity Server HMM...
Page 265: ...Related service information 257...
Page 278: ...270 Netfinity Server HMM...
Page 279: ...Related service information 271...
Page 280: ...272 Netfinity Server HMM...
Page 290: ...IBM Part Number 37L5123 Printed in U S A S37L 5123...