Power Fault Message in
the System Error Log
Failing FRU/Action
12V bus A
(power to PCI slots)
1. Disconnect AC
power.
2. Remove all PCI
adapters except the
I\O function card and
the system
management adapter.
3. Reconnect the AC
power and wait about
30 seconds for the
system management
adapter to initialize.
4. Attempt to start the
system. If the system
starts, one of the FRUs
removed is the failing
FRU. Reinstall the
FRUs one at a time to
identify the failing FRU.
5. If the system does not
start, suspect FRUs in
the following order:
a. I/O Function card
b. System
management
adapter
c. I/O board
d. Midplane
e. Power supply
12V bus B
(power to media devices
and I/O fans)
1. Disconnect AC
power.
2. Remove all internal
media devices (DASD,
CD-ROM, tape, and
floppy drives).
3. Remove the SCSI
backplane.
4. Remove all the I/O
fans (4, 5, and 6)
5. Reconnect the AC
power and wait about
30 seconds for the
system management
adapter to initialize.
6. Attempt to start the
system. If the system
starts, one of the FRUs
removed is the failing
FRU. Reinstall the
FRUs one at a time to
identify the failing FRU.
7. If the system does not
start, suspect FRUs in
the following order:
a. Midplane
b. Power control
card
c. Power supply
Netfinity 8500R - Type 8681
181
Summary of Contents for 8500R - Netfinity - 8681
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 25: ...1 LVD low voltage differential Netfinity 8500R Type 8681 17...
Page 62: ...Caution Use safe practices when lifting 54 Netfinity Server HMM...
Page 242: ...I O Housing Assembly 1 2 3 4 5 6 7 234 Netfinity Server HMM...
Page 261: ...Related service information 253...
Page 262: ...254 Netfinity Server HMM...
Page 263: ...Related service information 255...
Page 264: ...256 Netfinity Server HMM...
Page 265: ...Related service information 257...
Page 278: ...270 Netfinity Server HMM...
Page 279: ...Related service information 271...
Page 280: ...272 Netfinity Server HMM...
Page 290: ...IBM Part Number 37L5123 Printed in U S A S37L 5123...