Off Line Diagnostic Error Codes
D-19
Error
Number
Description
Failure
Percent
(%)
Failing
Function
Codes
Source
403-506
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
IOD-HW-STS register error.
Action: Use MAP 0210.
403-507
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
IRR register error.
Action: Use MAP 0210.
403-508
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
No external interrupt.
Action: Use MAP 0210.
403-509
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
External interrupt return error.
Action: Use MAP 0210.
403-510
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
Target processor error.
Action: Use MAP 0210.
403–511
K
C59
169
C62
C63
50
25
25
25
Description: BUMP to CPU interrupt error.
Not responding BUMP error.
Action: Use MAP 0210.
403-512
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
IRR4 register error.
Action: Use MAP 0210.
403-513
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
IOD-HW-STS register error.
Action: Use MAP 0210.
403-514
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
XIRR0 register error.
Action: Use MAP 0210.
403-515
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
XIRR4 register error.
Action: Use MAP 0210.
403-516
K
C59
C61
C63
50
25
25
Description: BUMP to CPU interrupt error.
IRR register error.
Action: Use MAP 0210.
403-520
K
C59
C61
C63
50
25
25
Description: CPU to BUMP interrupt.
IOD-HW-STS register error, bit i#1.
Action: Use MAP 0210.
403-521
K
C59
C61
C63
50
25
25
Description: CPU to BUMP interrupt.
IOD-HW-STS register error, bit i#0.
Action: Use MAP 0210.
403-522
K
C59
C61
C63
50
25
25
Description: CPU to BUMP interrupt.
CPU not responding.
Action: Use MAP 0210.
403-523
K
C59
C61
C62
C63
C65
50
25
25
25
25
Description: CPU to BUMP interrupt.
No External Interrupt.
Action: Use MAP 0210.
403-525
K
C59
C61
C63
50
25
25
Description: CPU to BUMP interrupt.
IOD-HW-STS register error.
Action: Use MAP 0210.
Summary of Contents for 7015-R30
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......