Using SystemGuard
2-21
Maintenance Menu
The MAINTENANCE MENU also enables you to display the configuration of the system in a
non-cryptic, easily understandable way, to perform various tests, to continue IPL either from
network, a specific SCSI device or from the boot list, and to set flags concerning various
system operation.
The MAINTENANCE MENU can only be entered by:
1. Enabling the BUMP Console from the STAND-BY MENU.
2. Setting the Autoservice IPL flag to disabled (the default value for this flag is disabled)
from the STAND-BY MENU.
3. Having a Valid Service Contract.
4. Turning the System Key to the Service position.
5. Powering-on the system.
The MAINTENANCE MENU shown below should appear just after the
292
code is
displayed on both the console and the LCD.
For Details,
MAINTENANCE MENU (Rev. XX)
See the
Following
Pages
2-22 0> DISPLAY CONFIGURATION
2-25 1> DISPLAY BUMP ERROR LOG
2-25 2> ENABLE SERVICE CONSOLE
2-25 3> DISABLE SERVICE CONSOLE
2-25 4> RESET
2-25 5> POWER OFF
2-26 6> SYSTEM BOOT
2-28 7> OFF–LINE TESTS
2-32 8> SET PARAMETERS
2-38 9> SET NATIONAL LANGUAGE
SELECT: