3-1520-8
Service Guide
Step 11
(from Step 10)
An over temperature problem can be caused by an environmental problem (see
Specifications in Chapter 1) or blocked air ducts. Check each of these items.
Did you find the problem?
NO
Go to Step 12.
YES
Repair the problem. Go to “Map 0410: Repair Checkout” in the
Diagnostic
Information For Micro Channel Bus Systems.
Step 12
(from Steps 10 and 11)
Is bit 1 a zero?
NO
If the SRN is 409-Axy, replace the main power supply. If the SRN is
409-Bxy, replace the backup power supply.
If the symptom did not change, reinstall the original power supply. Call your
service support person for assistance.
Go to “Map 0410: Repair Checkout” in the
Diagnostic Information For Micro
Channel Bus Systems.
YES
Go to “MAP 1540: CPU Enclosure - Minimum Configuration” on page
3-1540-1.