Service Guide
D-6
Error
Number
Source
Failing
Function
Codes
Failure
Percent
(%)
Description
401-514
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
APR register error.
Action: Use MAP 0210.
401-515
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
BSR init value.
Action: Use MAP 0210.
401-516
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
MD0 init value.
Action: Use MAP 0210.
401-517
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
MD1 init value.
Action: Use MAP 0210.
401-518
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
XIVR6 init value.
Action: Use MAP 0210.
401-519
K
C59
C63
C61
50
25
25
Description: Direct IO: IONIAN-SSGA.
DSIER init value.
Action: Use MAP 0210.
401-520
K
C59
100
Description: Direct IO. IONIAN register access error.
Action: Use MAP 0210.
401-521
K
C59
C61
80
20
Description: Direct IO. SSGA POS register error.
Action: Use MAP 0210.
401-522
K
C59
C61
80
20
Description: Direct IO. SSGA interrupt register error.
Action: Use MAP 0210.
401-523
K
C59
C90
MCA
adapters
25
25
50
Description: Direct IO: IONIAN-SSGA. IER register error on Base
Unit.
Action: Use MAP 0210.
401-524
K
C59
C90
MCA
adapters
25
25
50
Description: Direct IO: IONIAN-SSGA. IER register error on Base
Unit.
Action: Use MAP 0210.
401-530
K
C59
C61
80
20
Description: Direct IO. NVRAM data lines access error.
Action: Use MAP 0210.
401-531
K
C59
C61
80
20
Description: Direct IO. NVRAM address lines access error.
Walking 1 phase.
Action: Use MAP 0210.
401-532
K
C59
C61
80
20
Description: Direct IO. NVRAM address lines access error.
Walking 0 phase.
Action: Use MAP 0210.
401-540
K
C59
C61
80
20
Description: Direct IO. Super IO UART1 access error.
Action: Use MAP 0210.
401-541
K
C59
C61
80
20
Description: Direct IO. Super IO UART2 access error.
Action: Use MAP 0210.
401-542
K
C59
C61
80
20
Description: Direct IO. 16550 UART access error.
Action: Use MAP 0210.
401-543
K
C59
C61
80
20
Description: Direct IO. Floppy disk access error.
Action: Use MAP 0210.
401-544
K
C59
C61
80
20
Description: Direct IO. BPP register access error.
Action: Use MAP 0210.
Summary of Contents for 7015-R30
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......