Service Guide
D-24
Error
Number
Description
Failure
Percent
(%)
Failing
Function
Codes
Source
408-060
K
B94
B96 or
B97
50
50
Description: Main memory Knaizuk-Hartmann test error.
Action: Use MAP 0210.
408-080
K
C63
C61
90
10
Description: Multi resources full test error.
Action: Use MAP 0210.
409-000
K
???
100
Description: Planar vital part FATAL ERROR.
Action: Use MAP 0210.
409-008
K
B94 or C64
or D28
100
Description: No 2MB available in MM. All memory banks FATAL
ERROR.
Action: Use MAP 0210.
409–050
K
None
None
Description: This is not an error. This code indicates a change in
configuration, that NV-RAM has been reset, etc. No parts should
be replaced for this code.
409–051
K
None
None
Description: This is not an error. This code indicates a change in
configuration, that NV-RAM has been reset, etc. No parts should
be replaced for this code.
409–052 T1 x
K
Firmware
100
Description: –12 stand–by VOLT error. x is the unit number.
409–052 T2 x
K
Firmware
100
Description: +12 stand–by VOLT error. x is the unit number.
409–053 T1 x
K
Firmware
100
Description: 485RX protocol error (lengths). x is the unit number.
409–053 T2 x
K
Firmware
100
Description: 485RX protocol error (time–out). x is the unit number.
409–053 T3 x
K
Firmware
100
Description: 485RX protocol error (checksum error). x is the unit
number.
409–054 T1
K
Firmware
100
Description: Marginature error (ASIC VOLT).
409–054 T2
K
Firmware
100
Description: Marginature error (CPU VOLT).
409–054 T3 x
K
Firmware
100
Description: Marginature error (+5 VOLT). x is the unit number.
409–055 T1
K
Firmware
100
Description: VPD command error (read VPD).
409–055 T2
K
Firmware
100
Description: VPD command error (write VPD).
409–056
K
Firmware
100
Description: Marginature command error.
409–057
K
Firmware
100
Description: Checksum logging not valid.
409–058
K
Firmware
100
Description: Environment over temperature.
409–059 T1
K
Firmware
100
Description: I2C bus error (wrong interrupt frame).
409–059 T2 x
K
Firmware
100
Description: I2C bus error ( unknown SIB interrupt). x is the unit
number.
409–059 T3 x
K
Firmware
100
Description: I2C bus error ( unknown interrupt source). x is the
unit number.
409–059 T4 x
K
Firmware
100
Description: I2C bus error ( unknown operator panel interrupt).
x is the unit number.
409-080
K
C59
C60
C88 or C89
33
33
33
Description: BUMP access to OPP or OPP access to SIF failed.
Action: Use MAP 0210.
409-081
K
C59
C88 or C89
50
50
Description: BUMP access to SIF failed.
Action: Use MAP 0210.
409-082
K
C59
C60
80
20
Description: Operator panel cannot access the BUMP.
Action: Use MAP 0210.
Note: This problem can be caused by an incorrectly installed CEC.
Summary of Contents for 7015-R30
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......