Service Guide
Working with SystemGuard
SystemGuard parameters and flags may be changed from different locations. They can be
changed from the SystemGuard STAND-BY MENU, the SystemGuard MAINTENANCE
MENU, the Diagnostics interface, and also from AIX.
When the key signal is received, SystemGuard clears the screen and displays the
SystemGuard prompt. At this point, a keyword can be entered. The supported keywords are:
power
This keyword starts the system, exactly as if the power button is pushed.
You can change, disable or enable this keyword: see “Power-On Command
Parameters” on page 2-33 for details. Turning the system power on makes
the system enter the init phase. Thus, if the Key Mode Switch is in the
Service position, and if the
AutoService IPL flag is disabled, you enter the
Maintenance Menu.
sbb
This keyword displays the STAND-BY menu.
It is important to understand the following flowchart.
“Stand-By”
on Operator
Panel Display
Stand-By
Mode
Stand-
By
Menu
Service
System
Key
Position
Normal and Secure
Exit
Enter “sbb”
(>) Console Prompt
Enter “power”
System
Key
Position
Service
BUMP
Console
Enabled
No
Auto
Service IPL
Disabled
No
Yes
Secure
Multi-User
AIX
Maintenance
Menu
Stall State
Diagnostics
Normal
Press the Enter key
Yes
Summary of Contents for 7015-R30
Page 1: ...7015 Models R30 R40 and R50 CPU Enclosure Installation and Service Guide...
Page 10: ...x Service Guide...
Page 14: ...xiv Service Guide...
Page 34: ...1 20 Service Guide...
Page 214: ...6 10 Service Guide Detail 5 CPU Module 2 of 3 26 27 29 30 31 32 33 34 28 35...
Page 216: ...6 12 Service Guide Detail 6 CPU Module 3 of 3 36 37...
Page 252: ...B 8 Installation and Service Guide...
Page 288: ...Service Guide D 30...
Page 299: ......