Devices List
Follow the instructions on the screen for the installed devices list.
Attention:
A customized setup configuration (other than default settings) might exist on the
computer you are servicing. Running the Configuration/Setup Utility program (see
“Service Processor Configuration / Setup Utility” on page H-9) might alter those
settings. Note the current configuration settings and verify that the settings are in
place when service is complete.
If the number of diskette drives shown in the installed devices list is not
correct, do the following.
1. Restart the computer.
2. Run the Configuration/Setup Utility program to correct the drive information.
3. Run the diagnostic tests.
4. If you cannot correct the drive information, replace FRUs, in the following order,
until the problem goes away:
¹
Diskette drive
¹
Diskette-drive cable
¹
System board
If the number of hard disk drives shown in the installed devices list is not
correct, do the following.
1. Check the hard disk drive jumper settings. All supported hard disk drives use
jumpers or tabs to set drives as either primary or secondary. Refer to the
jumper instructions that came with your hard disk drives.
2. Check the voltages to the hard disk drives (see “Power-Supply” on page 3-21).
3. Restart the computer and check the configuration.
¹
If the first drive is missing, replace the primary drive.
¹
If any other drive is missing, replace that drive.
¹
If all drives are missing, replace the primary drive.
¹
If the problem remains, replace the drive cable.
¹
If the problem still remains, replace the system board.
If any other adapter or device is missing from the installed devices list, run
the Configuration/Setup Utility program. Check to see if any adapter or device
is set to a conflicting address with any other adapter or device. Also be sure that
any adapter or device missing from the list is not set to “disabled.”
Note: If the device is still missing from the list, run the diagnostics provided with
that device.
3-24
3745-XXA 3-24 3746-9X0: 6563 SPIM
Summary of Contents for 3745 Series
Page 2: ......
Page 10: ...viii 3745 XXA viii 3746 9X0 6563 SPIM...
Page 20: ...xviii 3745 XXA xviii 3746 9X0 6563 SPIM...
Page 24: ...xxii 3745 XXA xxii 3746 9X0 6563 SPIM...
Page 74: ...1 50 3745 XXA 1 50 3746 9X0 6563 SPIM...
Page 170: ...5 22 3745 XXA 5 22 3746 9X0 6563 SPIM...
Page 172: ...c If you have a problem call your support for assistance 6 2 3745 XXA 6 2 3746 9X0 6563 SPIM...
Page 182: ...A 10 3745 XXA A 10 3746 9X0 6563 SPIM...
Page 183: ...Appendix A Safety Information A 11...
Page 190: ...A 18 3745 XXA A 18 3746 9X0 6563 SPIM...
Page 200: ...C 6 3745 XXA C 6 3746 9X0 6563 SPIM...
Page 204: ...E 2 3745 XXA E 2 3746 9X0 6563 SPIM...
Page 243: ...Appendix I Service Processor Part Numbers Copyright IBM Corp 1999 I 1...
Page 244: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 I 2 3745 XXA I 2 3746 9X0 6563 SPIM...
Page 246: ...I 4 3745 XXA I 4 3746 9X0 6563 SPIM...
Page 269: ......
Page 270: ...Part Number 10K8590 Printed in U S A 10K8590 SY27 0393 00...