Chapter 2 Wiring
POWER CON
PCON-CB/LC
56
[2] PIO Pattern 7 (Incremental Type for Actuator)
The table below shows the signal assignment of the flat cable in the “pulse train control mode” to PIO Pattern 6.
Follow the following table to connect the external equipment (such as host unit).
Pin
No. Category I/O No.
Signal
Abbreviation
Signal Name
Function Description
Relevant
Sections
1A
24V
P24
Power Supply
Power Supply for I/O +24V
2A
24V
P24
Power Supply
Power Supply for I/O +24V
3A
PP
Differential Pulse Train
Input (+)
4A
Pulse
Input
/PP
Differential Pulse Train
Input (-)
Input the differential pulse from the host.
Input is available up to 200kpps at maximum.
2.2.3 [4]
3.3.3 [1]
5A
IN0
SON
Servo ON
The servo remains ON while this signal is ON, or
OFF while this signal is OFF.
3.3.2 [5]
6A
IN1
RES
Reset
Turn the signal ON to reset the alarm.
3.3.2 [10]
7A
IN2
HOME
Home Return
The controller will perform home return operation
when this signal is turned ON.
3.3.2 [6]
8A
IN3
TL
Torque Limit Select
Applies torque limit to the motor with the signal ON
and the value set to the parameter.
3.3.3 [3]
9A
IN4
CSTP
Compulsory Stop
Turning it ON continuously for more than 16ms
forcibly stops the actuator.
The actuator decelerates then stops with the torque
set in the controller and then turns the servo OFF.
3.3.2 [4]
10A
IN5
DCLR
Deviation Counter Clear Clears the deviation counter.
3.3.3 [4]
11A
IN6
BKRL
Brake Release
The brake will forcibly be released.
3.3.2 [11]
12A
IN7 RMOD
Operation Mode
Changeover
The operating mode is selectable when the MODE
switch of the controller is set to AUTO.
(The setting is AUTO when signal is OFF, and
MANU when ON.)
3.3.2 [3]
13A
IN8 RSTR
Datum Position
Movement Command
Applies torque limit to the motor with the signal ON
and the value set to the parameter No.167
3.3.2 [8]
14A
IN9
NC
–
Not used
15A
IN10
NC
–
Not used
16A
IN11
NC
–
Not used
17A
IN12
NC
–
Not used
18A
IN13
NC
–
Not used
19A
IN14
NC
–
Not used
20A
Input
IN15
NC
–
Not used
1B
OUT0
PWR
System Ready
It turns ON when the control becomes available
after the main power is supplied.
3.3.2 [1]
2B
OUT1
SV
Servo ON Status
This signal will remain ON while the servo is ON.
3.3.2 [5]
3B
OUT2
INP
Position Complete
Turned ON when the remaining moving pulses in
the deviation counter enters within the positioning
band.
3.3.3 [2]
4B
OUT3
HEND
Home return completion This signal will turn ON when home return has been
completed.
3.3.2 [6]
5B
OUT4
TLR
Torque Under Control
Turns ON if the torque reaches the limit value
during torque limit.
3.3.3 [3]
6B
OUT5
*ALM
Controller Alarm Status Turns ON when controller in normal condition, and
OFF when alarm is generated.
3.3.2 [10]
7B
OUT6
*EMGS
Emergency Stop Status Turns ON when the controller emergency stop is
cancelled, and OFF during the emergency stop.
3.3.2 [2]
8B
OUT7
RMDS
Operation Mode Status The operating mode status will be output. It turns
ON when the controller is on Manual Mode.
3.3.2 [3]
9B OUT8
ALM1
10B OUT9
ALM2
11B OUT10
ALM4
12B OUT11
ALM8
Alarm Code Output
Signal
The alarm code is output together with the alarm
signal output.
Refer to Alarm List for details.
3.3.2 [11]
13B
OUT12
*ALML
Light Error Alarm
Outputs when a message level alarm is generated. 9.4
14B OUT13
REND
Datum Position
Movement Complete
Turns on when movement to the datum position set
in Parameter No.167 is finished.
3.3.2 [8]
15B
OUT14
ZONE1
Zone Signal 1
16B
Output
OUT15
ZONE2
Zone Signal 2
This signal will turn ON when the current actuator
position enters the range set by the parameters.
3.3.2 [9]
17B
NP
Differential Pulse Train
Input (+)
18B
Pulse
Input
/NP
Differential Pulse Train
Input (-)
Input the differential pulse from the host.
Input is available up to 200kpps at maximum.
2.2.3 [4]
3.3.3 [1]
19B
0V
N
Power Supply
Power Supply for I/O 0V
20B
0V
N
Power Supply
Power Supply for I/O 0V
Signal with “*” expresses the signal of active low. It is ON when the power is applied to the controller, and turns OFF
when the signal is output.
Summary of Contents for PCON-CB series
Page 2: ......
Page 4: ...POWER CON PCON CB LC ...
Page 14: ...POWER CON PCON CB LC ...
Page 32: ...POWER CON PCON CB LC 18 ...
Page 84: ...Chapter 2 Wiring POWER CON PCON CB LC 70 ...
Page 174: ...Chapter 4 Field Network POWER CON PCON CB LC 160 7 EtherCAT Type 8 PROFINET IO Type ...
Page 190: ...Chapter 7 Absolute Reset and Absolute Battery POWER CON PCON CB LC 176 ...
Page 226: ...Chapter 8 Parameter POWER CON PCON CB LC 212 ...
Page 330: ...Chapter 10 Appendix POWER CON PCON CB LC 316 ...
Page 334: ......