2.3.3 Connection of PIO
Conduct the connection of I/O to the controller is to be carried out using the dedicated I/O cable.
The cable length is shown in the model code of the controller. Please check the controller
model code. There are 2m for standard, 3m and 5m as an option. Up to 10m I/O cables are
sold separately. [Refer to 1.1.5 How to read the model]
Also, the end of the cable harness to be connected to the host controller (PLC, etc.) is just cut
and no treatment is conducted so the wiring layout can be performed freely.
Model : CB-PAC-PIO
□□□
(
□□□
indicates the cable length L. Example. 020 = 2m)
No.
Cable
Color
Wiring
No.
Cable
Color
Wiring
1A BR-1
1B BR-3
2A RD-1
2B RD-3
3A OR-1
3B OR-3
4A YW-1
4B YW-3
5A GN-1
5B GN-3
6A BL-1
6B BL-3
7A PL-1
7B PL-3
8A GY-1
8B GY-3
9A WT-1
9B WT-3
10A BK-1
10B
BK-3
11A BR-2
11B BR-4
12A RD-2
12B
RD-4
13A OR-2
13B
OR-4
14A YW-2
14B
YW-4
15A GN-2
15B
GN-4
16A BL-2
16B
BL-4
17A PL-2
17B
PL-4
18A GY-2
18B
GY-4
19A WT-2
19B
WT-4
20A BK-2
Flat Cable
○
A
(Press Welding)
AWG28
20B
BK-4
Flat Cable
○
B
(Press Welding)
AWG28
For the signal assignment of each wire, refer to the following considering the operation mode.
1) Positioner Mode ························ 2.1.3 [4] PIO Circuit
2) Pulse Train Control Mode ············ 2.2.3 [3] PIO Circuit
Summary of Contents for PCON-CB series
Page 2: ......
Page 4: ...POWER CON PCON CB LC ...
Page 14: ...POWER CON PCON CB LC ...
Page 32: ...POWER CON PCON CB LC 18 ...
Page 84: ...Chapter 2 Wiring POWER CON PCON CB LC 70 ...
Page 174: ...Chapter 4 Field Network POWER CON PCON CB LC 160 7 EtherCAT Type 8 PROFINET IO Type ...
Page 190: ...Chapter 7 Absolute Reset and Absolute Battery POWER CON PCON CB LC 176 ...
Page 226: ...Chapter 8 Parameter POWER CON PCON CB LC 212 ...
Page 330: ...Chapter 10 Appendix POWER CON PCON CB LC 316 ...
Page 334: ......
Page 335: ......