Chapter 1 Specifications Check
POWER CON
PCON-CB/LC
33
1.5 Options
1.5.1 Pulse converter : AK-04
The pulse converter converts command pulses in the open collector mode to those in the
differential mode.
Use this converter if the host controller sends output pulses in the open collector mode.
Item Specification
Input Power Supply
24V DC
±
10% (MAX. 50mA)
Input Pulse
O/C (Collector current MAX. 12mA)
Input Frequency
200kpps or less
Output Pulse
Differential output equivalent to 26C31 (MAX. 10mA)
Mass
10g or less (excluding cable connector)
Accessories
37104-3122-000FL (e-CON Connector) 2 Units
Cover Color : YW
Applicable wire AWG No.24 to 26 (Less than 0.14 to
0.3mm
2
, finished O.D.
φ
1.0 to 1.2mm)
Caution
1) Use the pulse converter in the surrounding temperature range between 0
°
C and 40
°
C.
2) The temperature increase of about 30
°
C occurs during operation. Accordingly, neither
install several pulse converters in close contact nor install them within a duct. Do not
install the pulse converter near other heating devices.
3) If more than one pulse converter are installed, set a pulse converter apart from another by
10mm or more.
Summary of Contents for PCON-CB series
Page 2: ......
Page 4: ...POWER CON PCON CB LC ...
Page 14: ...POWER CON PCON CB LC ...
Page 32: ...POWER CON PCON CB LC 18 ...
Page 84: ...Chapter 2 Wiring POWER CON PCON CB LC 70 ...
Page 174: ...Chapter 4 Field Network POWER CON PCON CB LC 160 7 EtherCAT Type 8 PROFINET IO Type ...
Page 190: ...Chapter 7 Absolute Reset and Absolute Battery POWER CON PCON CB LC 176 ...
Page 226: ...Chapter 8 Parameter POWER CON PCON CB LC 212 ...
Page 330: ...Chapter 10 Appendix POWER CON PCON CB LC 316 ...
Page 334: ......
Page 335: ......