Chapter 3 Operation
POWER CON
PCON-CB/LC
151
[3] Torque Limit Select (TL, TLR)
Input Output
PIO signal
TL TLR
This signal is used to limit the torque of the motor.
While the TL signal is ON, the actuator thrust (motor torque) can be limited to the torque set
in Parameter No.57 “Torque limit”.
With the TL signal being ON, the TLR signal (torque limiting) will turn ON when the actuator
thrust reaches the torque limit.
The TL signal is disabled during home return or forced stop.
Caution:
• Do not turn the TL signal OFF while the TLR signal is ON.
• An excessive deviation (accumulated pulses) may generate while torque is being limited
(TL signal is ON) (for example, the actuator may receive a load just like it receive a
pressing force in pressing operation and therefore become no longer operable). If the TL
signal is turned OFF in this condition, actuat
or control will start at
the maximum torque the
moment the signal changes, thus causing the actuator to move suddenly or run
uncontrollably. After turning TLR signal ON, perform an operation in the reversed way to
confirm TLR signal turns OFF. If the condition is difficult for the reversed movement, turn
the servo OFF or clear the deviation counter (by turning DCLR ON).
[4] Deviation Counter Clear (DCLR)
Input
PIO signal
DCLR
This is the signal to clear the deviation counter
that stores the specified pulse until its process
is completely finished (positioning is completed) once a command pulse is input.
It is used when the deviation is desired to be cleared after the pressing by TL signal is
complete (TLR signal ON). Once the deviation is cleared, TLR signal turns OFF and the
condition can be made as it is positioned at the point where the pressing is complete.
Caution: DCLR signal is a signal that is pr
ocessed at the startup (ON edge). Therefore,
input the pulse train while DCLR signal
is on and the actuator will operate.
Turn this signal ON only when the deviation counter is to be cleared.
Summary of Contents for PCON-CB series
Page 2: ......
Page 4: ...POWER CON PCON CB LC ...
Page 14: ...POWER CON PCON CB LC ...
Page 32: ...POWER CON PCON CB LC 18 ...
Page 84: ...Chapter 2 Wiring POWER CON PCON CB LC 70 ...
Page 174: ...Chapter 4 Field Network POWER CON PCON CB LC 160 7 EtherCAT Type 8 PROFINET IO Type ...
Page 190: ...Chapter 7 Absolute Reset and Absolute Battery POWER CON PCON CB LC 176 ...
Page 226: ...Chapter 8 Parameter POWER CON PCON CB LC 212 ...
Page 330: ...Chapter 10 Appendix POWER CON PCON CB LC 316 ...
Page 334: ......
Page 335: ......