Chapter 8 Parameter
POWER CON
PCON-CB/LC
181
I/O Parameter List (Continued)
No.
C
at
eg
or
y
Name
Symbol
Unit
Input Range
Default factory
setting
for
Positioner
Mode
for Pulse
Train
Mode
Relevant
sections
140 B IP address
IPAD
–
0.0.0.0 to
255.255.255.255
Separate volume
{
{
Separate
volume
141 B Subnet mask
SNMK
–
0.0.0.0 to
255.255.255.255
Separate volume
{
{
Separate
volume
142 B Default gateway
DFGW
–
0.0.0.0 to
255.255.255.255
Separate volume
{
{
Separate
volume
143 B Overload level ratio
OLWL
%
50 to 100
100
{
8.2 [77]
144 B Gain scheduling upper limit
multiplying ratio
GSUL
%
0 to 1023
0
{
8.2 [78]
145 C GS velocity loop proportional gain
GSPC
–
1 to 30000
750
{
8.2 [79]
146 C GS velocity loop integral gain
GSIC
–
1 to 500000
4500
{
8.2 [80]
147 B Total movement count threshold
TMCT
Times
0 to 999999999
0 (Disabling)
{
8.2 [81]
148 B Total operated distance threshold
ODOT
m
0 to 999999999
0 (Disabling)
{
{
8.2 [82]
149 B Zone output changeover
FPIO
–
0: To change
1: Not to change
0
{
8.2 [83]
151 B Light malfunction alarm output
select
OALL –
0: Overload warning
output
1: Message lebel alarm
output
0
{
{
9.2 [84]
152 B High output setting
BUEN
–
0: Disabling
1: Enabling
In accordance with
actuator
(Note2)
{
{
8.2 [85]
153 B BU velocity loop proportional gain
BUPC
–
1 to 10000
200
{
8.2 [86]
154 B BU velocity loop integral gain
BUIC
–
1 to 100000
4000
{
8.2 [87]
155 A Absolute battery retention time
AIP
–
0: 20 days
1: 15 days
2: 10 days
3: 5 days
0
{
8.2 [88]
156 B Torque check/Light malfunction
output select
SLAL –
0: Torque check effective
1: Light malfunction
effective
0
{
{
8.2 [89]
159 B FB half direct mode speed unit
(Note 4)
FBVS –
0: Units of 1mm/s
1: Units of 0.1mm/s
Separate volume
{
Separate
volume
165 B Delay time after shutdown release
SDDT
msec
0 to 100
0
{
{
8.2 [92]
166 B Startup current limit extension
feature
DCET –
0: Disabling
1: Enabling
In accordance with
actuator
(Note2)
{
{
8.2 [93]
167 B Pulse train datum position
RPOS
mm
-9999.99 to 9999.99
0
{
8.2 [94]
168 B Collision detection feature
CODT
–
0 to 7
0
{
{
8.2 [95]
182 B Automatic current reduction feature
select
ACDS –
0: Disabling
1: Enabling
0
{
6.2
Note 2 The setting values vary in accordance with the specification of the actuator. At shipment, the
parameters are set in accordance with the specification.
Note 4 These parameters are exclusively used for the fieldbus type.
Caution: Make sure to set to “Positioner Mode” (No. 25 PIO Pattern = 0 to 5) when performing
an operation with using the serial communication.
If it happens to be in the “pulse train mode” by mistake, the controller may operate
erratically because it is operated according to the “pulse train mode” parameters.
Summary of Contents for PCON-CB series
Page 2: ......
Page 4: ...POWER CON PCON CB LC ...
Page 14: ...POWER CON PCON CB LC ...
Page 32: ...POWER CON PCON CB LC 18 ...
Page 84: ...Chapter 2 Wiring POWER CON PCON CB LC 70 ...
Page 174: ...Chapter 4 Field Network POWER CON PCON CB LC 160 7 EtherCAT Type 8 PROFINET IO Type ...
Page 190: ...Chapter 7 Absolute Reset and Absolute Battery POWER CON PCON CB LC 176 ...
Page 226: ...Chapter 8 Parameter POWER CON PCON CB LC 212 ...
Page 330: ...Chapter 10 Appendix POWER CON PCON CB LC 316 ...
Page 334: ......
Page 335: ......