Chapter 3 Operation
POWER CON
PCON-CB/LC
129
[Operation of Slider Type/Rod Type Actuator]
1) With the ST0 signal being ON, the actuator moves toward the mechanical end at the home
return speed.
The moving speed is 20mm/s for most actuators but less than 20mm/s for some actuators.
Check the instruction manual of actuator.
2) The actuator is turned at the mechanical end and stopped at the home position. The
moving distance is the value set by Parameter No.22 “Home return offset level”.
Caution: In the home reverse specification, the actuator moves in the reverse direction.
Make sure to refer to Section 8.2 [16] when a change to Parameter No.22
“Home return offset level” is required.
[Operation of Rotary Actuator]
(1) 330
°
Rotation Specification
1) With the HOME signal being ON, the actuator rotates at 20deg/s in the CCW
(counterclockwise) direction when it is viewed from the load side.
2) It reverses at the mechanical stopper and stops at the home position. The movement
amount in this process follows the setting in Parameter No.22 “Home return offset level”.
Caution: Make sure to refer to Section 8.2 [16] when a change to Parameter No.22
“Home return offset level” is required.
Mechanical end
Home
1)
2)
Home = 0
°
Mechanical stopper
1)
2)
Summary of Contents for PCON-CB series
Page 2: ......
Page 4: ...POWER CON PCON CB LC ...
Page 14: ...POWER CON PCON CB LC ...
Page 32: ...POWER CON PCON CB LC 18 ...
Page 84: ...Chapter 2 Wiring POWER CON PCON CB LC 70 ...
Page 174: ...Chapter 4 Field Network POWER CON PCON CB LC 160 7 EtherCAT Type 8 PROFINET IO Type ...
Page 190: ...Chapter 7 Absolute Reset and Absolute Battery POWER CON PCON CB LC 176 ...
Page 226: ...Chapter 8 Parameter POWER CON PCON CB LC 212 ...
Page 330: ...Chapter 10 Appendix POWER CON PCON CB LC 316 ...
Page 334: ......
Page 335: ......