CONTROL SYSTEM
TNV Application Manual
2-65
Alarm/failure detection conditions depend on the setting of the flags shown in
Table 2-20 Alarm/failure detection condition setting flags
No.
Alarm/failure
Detection condition setting flag
26
Coolant temperature high alarm
Coolant temperature alarm setting flag
2
Accelerator sensor failure
APS terminal function assignment flag
3
Backup speed sensor activation
RENRPM terminal function assignment flag
8
CAN communication failure
Application setting flag
9
EGR valve failure
EGR valve setting flag
11
Air heater relay failure
Starting aid relay failure detection setting flag
14
Backup accelerator sensor failure
REAN terminal function assignment flag
15
Atmospheric pressure sensor failure
16
Oil pressure switch failure
APP-IP2 terminal function assignment flag
17
Charge switch failure
APP-IP3 terminal function assignment flag
21
Oil pressure low
APP-IP2 terminal function assignment flag
22
Charge failure
APP-IP3 terminal function assignment flag
23
Coolant temperature abnormal
APP-IP4 terminal function assignment flag
24
Air cleaner blockage alarm
APP-IP5 terminal function assignment flag
25
Oily water separator alarm
APP-IP6 terminal function assignment flag
20
E-ECU overheat alarm
E-ECU overheat alarm setting flag
00_Electronic_Control_System.book 65 ページ 2006年5月29日 月曜日 午後2時12分
Summary of Contents for Yanmar 3TNV82A-B
Page 95: ...CONTROL SYSTEM 2 76 TNV Application Manual 00_Electronic_Control_System book 76...
Page 96: ...Appendix Standard harness 1 00_ _E fm 1...
Page 97: ...Appendix Standard harness 2 00_ _E fm 2...
Page 98: ...TNV Series service tool Operation Manual...
Page 132: ...32 7 Main Menu Figure 7 15 Data Logging Data Monitor Screen...
Page 145: ...7 Main Menu 45 Figure 7 27 System Installation Configuration Screen...